background image

Page 7 

 

Using the Boom Nozzles 

Four things must be considered before spraying with the boom. 

 

How much chemical must be mixed in the tank. 

 

Rate of spray (gallons per acre to be sprayed). 

 

What pressure (p.s.i.) will be used. 

 

Speed traveled (mph) while spraying. 

 

Refer to the chemical label to determine your chemical mixture 

 

See the tip chart to determine the pressure to be used. The chart will also show the speed used when spraying. 

 

Start the pump and open the valve to the boom nozzles. 

 

Check the spray pattern. Usually you can see the coverage better on a solid concrete surface, such as a driveway. 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as 

instructed after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s 

instructions on disposal of all waste water from the sprayer.

 

 

Storing Sprayer 

When sprayer is not in use, release Cam Lock Handles. This is to prevent deforming of Cam Lock Mechanism. Do not use QR bracket Cams to hold 

and store boom in vertical position. 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV 

antifreeze through the system. This will keep internal parts 

lubricated, protect against corrosion and keep the unit from 

freezing. 

Note: RV antifreeze is non-toxic and biodegradable 

and generally safer for the environment than automotive anti-

freeze.

 

Before storing your sprayer for winter or long term storage, 

thoroughly clean and drain it as much as possible. Then pour 

enough pink RV antifreeze into the tank so that when the 

pump is turned on you can pump the antifreeze throughout the 

entire plumbing system, including the bypass. Make sure to 

operate the boom and handgun until you see pink fluid spray-

ing from the nozzles. Leave any remaining antifreeze in the 

tank. Before your next usage, rinse the antifreeze from the 

sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer 

and any trapped water can freeze in cold weather and dam-

age parts of the sprayer. Pumping the antifreeze through the 

system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with 

fresh water and run through the system. Dispose of antifreeze 

and flush water properly. 

Speed Chart 

  

Time Required in seconds 

to travel a distance of 

Speed in M.P.H. 
(Miles Per Hour) 

100 Ft. 

200 Ft. 

300 Ft. 

1.0 

68 sec. 

136 sec.  

205 sec. 

2.0 

34 

68 

102 

3.0 

23 

45 

68 

4.0 

17 

34 

51 

5.0 

14 

27 

41 

6.0 

11 

23 

34 

7.0 

9.7 

19 

29 

8.0 

8.5 

17 

26 

9.0 

7.6 

15 

23 

10.0 

6.8 

14 

20 

Spray Tip Rate Chart (20" Spacing) 

Tip 

No. 

Spray 

Height 

Pressure 

(psi) 

Capacity 

(GPM) 

Gallons Per Acre - Based on Water 

MPH 

MPH 

MPH 

MPH 

MPH 

MPH 

MPH 

AIXR11002VP 

18" 

15 

.12 

35.6 

17.8 

11.8 

8.9 

7.1 

5.9 

4.5 

20 

.14 

41.6 

20.8 

13.8 

10.4 

8.3 

6.9 

5.2 

30 

.17 

50.4 

25.2 

16.8 

12.6 

10.1 

8.4 

6.3 

40 

.20 

59.6 

29.8 

19.8 

14.9 

11.9 

9.9 

7.4 

Tip 

No. 

Spray 

Height 

Pressure 

(psi) 

Capacity 

(GPM) 

Gallons Per 1000 Sq. Ft. - Based on Water 

MPH 

MPH 

MPH 

MPH 

MPH 

MPH 

MPH 

AIXR11002VP 

18" 

15 

.12 

  

.41 

.27 

.20 

.16 

  

  

20 

.14 

  

.48 

.32 

.24 

.19 

  

  

30 

.17 

  

.58 

.39 

.29 

.23 

  

  

40 

.20 

  

.68 

.45 

.34 

.27 

  

  

Try another 12-Volt battery

Quarter turn at a time clockwise until surging stops

Defective pressure switch

Troubleshooting

Bypass is not completely closed
System has leaks
Check for worn or dirty check valve
Excessive voltage
Improper adjustment of pressure switch
Damaged or defective wiring harness

Check for proper voltage

Check for worn or dirty check valve
Low flow may cause pump to surge
Spray wand is adjusted for a small or fine spray pattern
Slightly open bypass (if applicable) to overcome
If needed, pressure switch may need to be adjusted

Pump will not run:

Low Pressure/Low Flow:

Pump surges:

Pump continues to run:

Fuse blows:

Check for loose wiring
Make sure the ON/OFF switch is on
Check the fuse
Check for defective pressure switch
Check for a clogged strainer

Summary of Contents for 5302320

Page 1: ...hould already be attached to the tank IMPORTANT REMINDER This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If yo...

Page 2: ...carton ATV 25 700 QR 5302320 7 Nozzle Boom 5277780 7 Nozzle Harness 5277696 Nozzle Clamps Pkg of 7 5277730 Contents of Parts Bag 5278132 Tank Lid Lanyard 5058188 Contents of Bracket Kit 5278133 Tank Plumbing Pre Assembly Owner s Manual ...

Page 3: ... 4 flat head screws to secure it to the tank The tank will rest on the surface of the brack ets Make sure the brackets are parallel with each other before tightening down the bolts Do not over tighten After your tank brackets are securely attached turn the tank assembly over and position it so that the cam handles which extend beyond the back of the tank are facing you and just hanging over the ed...

Page 4: ...n be positioned as shown or in a few alternate positions Try to maintain approximately 18 22 inches above the items being sprayed for optimal coverage This is con sidered where the nozzles will mount at the end of these brackets With the boom secured to the boom mounting brack ets the nozzle harness can now be attached Attach the nozzle harness to the boom Using the nozzle clamps attach the nozzle...

Page 5: ...tall the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Place the end of the lanyard through the tab in the tank This is so the lid can hang off the tank when filling rinsing the tank out Detail C Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hol...

Page 6: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 7: ...orrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive anti freeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the ent...

Page 8: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Page 9: ...e replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires o...

Page 10: ...Page 10 Exploded View Parts List ATV 25 700 QR 5302320 Manifold Detail 5281538 Intake Assembly 5281145 ...

Page 11: ...10 tips and 20 spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction technology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance includ ing acids as well as exceptional wear life Compact size to prevent tip damage Ex...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: