background image

Page 7 

 

Manifold Valves CLOSED 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test. 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, then 

connect to the negative (black) terminal. Then connect the end of the lead wire to the end of 

the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then 

disconnect the negative (black) connection and finally the positive (red) connection. The lead 

wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved. 

Opening the valve decreases pressure, closing the valve increases pressure. When spraying with the boom, the proper method to set the pressure is 

to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pressure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 2 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Summary of Contents for 5302930

Page 1: ... Nozzles 18 x 8 5 x 8 Turf Tires Multi Lid OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In ...

Page 2: ...ayer s carton LG 50 TRL PRO BL Tank Plumbing Pre Assembly Owner s Manual Tongue Assembly Contents of Parts Bag 5281302 Boom Mount Kit 5281316 Wet Boom Sub Assembly End Nozzle 5275122 Pkg of 2 5275713 1 x 32 Axle Shaft Turf Tires ...

Page 3: ... Slide the wheel onto the axle making sure the valve stem is facing outward Retain the wheel on the axle with the hitch pin See Detail C Repeat for other side NOTE The wheels have grease zerks for bear ings After the wheels are installed the bearings should be filled with a NGLI No 2 lithium grease Once a year new grease should be added to each wheel Step 2 Detail B Detail C Step 3 Locate axle 2 1...

Page 4: ...it up to the tank Secure the holders in place Do Not Over Tighten Wrap the hose and slip in the handgun Install the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Step 4 Step 6 Locate the 2 boom mount brackets 4 5 16 18 x 9 16 x 2 3 16 square u bolts and 8 5 16 18 hex whiz nuts Mount the boom mount brackets on the upright boom arms as shown You can position them as needed just be sure th...

Page 5: ...n the boom tube item 2 is not in the correct placement End Nozzle Assembly Procedure For Boomless Wet Boom Your boom will come with the 2 end nozzle assemblies NOT affixed to your boom tube Follow the instructions below to attach these properly to the boom tube as shown Assembled End Nozzle 15 End Nozzle Information 5275122 This nozzle mounting stem Has a ratcheting motion Each click of the ratche...

Page 6: ...uts onto the u bolts Tighten just so that the boom tube will NOT rotate within the grommets Alternate the tightening of the locknuts to provide even pressure on the grommet DO NOT OVER TIGHTEN the whiz locknuts as this may cause the boom tube to flatten slightly After your boom is attached connect the feeder hose using 1 hose clamp Place the hose clamp loosely over the end of the hose Slip the end...

Page 7: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 8: ...e chemical manufacturer s instructions on disposal of all waste water from the sprayer NOTE The wheels have grease zerks for bearings Once a year new grease a NGLI No 2 lithium grease should be added to each wheel Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the u...

Page 9: ...Clean and rinse your pump after each use with Fimco Tank Neutralizer Winterize your pump or sprayer by rinsing draining and running RV Antifreeze through it before storing for the winter Use clean water for your spray mixture Store inside a building when not in use DON T Pulsating flow surging Check for defective pressure switch Check for leaks in the discharge line Check for restriction in the di...

Page 10: ...Page 10 Exploded View LG 50 TRL PRO BL 5302930 See Next Page for Parts List See Plumbing Detail Next Page See Boom Assembly Parts List Page 12 Bulkhead Fittings ...

Page 11: ...TRL PRO BL 5302930 This sprayer comes with an On Off shut off valve located just before the strainer You must make sure the valve is in the open position before using your sprayer Manifold Detail Plumbing Detail Intake Assembly ...

Page 12: ...Page 12 Boomless Wet Boom Assembly Exploded View Parts List 5275260 End Nozzle Assembly 5275122 Center Nozzle Assembly 5275123 ...

Page 13: ...Page 13 NOTES ...

Page 14: ... Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information about...