Thank you for purchasing this product. The purpose of this 

manual is to assist you in operating and maintaining your Skid 

Sprayer.  

www.fimcoindustries.com 

1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD  57049      

Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440 

[5004505   

 

 

 

 

 

(12/18)] 

Model: LSS-235 (5301070) 

(200 Gallon Lawn Service Skid-Mounted High Pressure Sprayer)

 

Technical Specifications 

 

200 Gallon Polyethylene Tank 

 

Maximum Flow = 10.6 GPM 

 

Maximum Pressure = 580 PSI 

 

Maximum Temperature = 140°F 

 

GunJet Spray Gun w/1/2” x 300’ of Hose 

 

Delta Jet Agitator 

 

Caution: When fully filled with water, this sprayer will 

weigh approx. 2,070 lbs..  

Consult the owner’s manual for your vehicle to verify 

that you are within it’s load carrying capacity.  

Retain a copy of your receipt for your unit,  

as it will be required to validate any warranty service 

Products are warranted against manufacturer or workmanship 

defects for one year from date of purchase for home owner  

usage and 90 days for commercial usage. 

 

For technical assistance, visit our website @ 

www.fimcoindustries.com or call: 

TOLL FREE @ 1-800-831-0027 

Our Technical Support Representatives will be happy to help you. 

To obtain prompt, efficient service, always remember to give the 

following information… 

 

Correct Part Description and/or part number 

 

Model #/Serial # of your sprayer 

Part descriptions and numbers can be obtained from the illustrated 

parts list section(s) of this manual. 

OWNER’S MANUAL

 

Before Operating the Sprayer 

 

1.  Add  proper  oil  to  the  engine  crankcase  and  gasoline  to 

the gas tank. Always check the oil in the gear box. Refer 

to engine manual for correct oil type. Add SAE 30 to the 

sight level in the diaphragm pump. Fill the gear case with 

90W gear lube until the gear lube runs out the side plug 

hole.  

2.  Add  plain  water  to  the  tank  and  check  the  system  for 

leaks. Open the suction line valve. Open the lever valves 

by the pressure regulator that are connected to the hand-

gun line and jet agitator line. 

3.  The pumping system includes an agitator, which will help 

keep the solution in suspension. Pressure to the agitator 

should  never  exceed  100  PSI.  When  spraying  at  pres-

sures over 100 PSI, use the valve (in the agitator line) to 

throttle  the pressure  to  the  agitator  by  closing  the  valve. 

The valve may be opened slowly until the gauge reaches 

100 PSI. 

 

Do not exceed recommended pressure on pump or  

sprayer, as it may cause hoses to burst and will shorten 

pump life.

 

***WARNING*** 

This product when used can be dangerous and can cause 

bodily harm, only if not properly used or guarded. 

* STAY AWAY FROM EQUIPMENT 

WHEN IT IS IN OPERATION * 

Read information and the full instructions furnished with the 

product 

before installing and operating. 

Summary of Contents for LSS-235

Page 1: ...ng information Correct Part Description and or part number Model Serial of your sprayer Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual OWNER S MANUAL Before Operating the Sprayer 1 Add proper oil to the engine crankcase and gasoline to the gas tank Always check the oil in the gear box Refer to engine manual for correct oil type Add SAE 30 to ...

Page 2: ... done after each 200 hours of use or at least once a season To fill the pump with oil pour oil slowly into the sight tube while slowly turning the pump shaft Turning the pump shaft purges all of the air from the crankcase Use SAE 30 motor oil Refer to the pump and motor owners manuals for their respective replacement parts and service recommendations After use fill the sprayer tank part way with w...

Page 3: ...ts List Mfg AA43H AL6 5014011 Delta Jet Agitator Orifice Color Orifice P S I Inlet Flow G P M Outlet Flow G P M Black 1 8 30 0 2 9 9 5 Red 5 32 30 0 4 1 13 2 Blue 3 16 30 0 5 3 15 4 White 1 4 30 0 6 5 19 5 Venturi action more than triples the effective flow of liquid for Operation As solution is forced through the agitator the venturi action triples the flow through the agitator The valve in the l...

Page 4: ...Page 4 Exploded View LSS 235 5301070 Refer to Parts List next page for Part Numbers ...

Page 5: ...ose Clamp 1 2 6 34 4 1 3351 0039 Strainer Bowl 1 21 5056097 Poly Elbow 11 16 MPS x 3 4 HB 1 34 4 2 5116131 Strainer Screen 40 Mesh 1 22 5067052 Steel Fitting 1 2 MPT x 1 2 HB 2 34 4 3 5072299 Strainer EPDM Gasket 1 23 5075014 Rubber Grommet Black 2 34 4 4 3351 0038 Strainer Cap 1 24 5108041 Tank Strap Buckle Bent 4 34 5 5038258 Strainer Bracket 1 25 5117301 1 4 20 x 1 Hex Flange Screw 2 34 6 50111...

Page 6: ...ach Screw 2 4 5117234 10 24 x 1 2 Phillips Truss Head Mach Screw 2 5 5117334 10 24 x 1 2 Phillips Round Head Mach Screw 1 6 5157025 Strain Relief 1 7 5157057 Auto Reset Circuit Breaker 40 Amp 1 8 5157075 Solenoid 12 Volt 1 9 5272286 Electrical Components Base Weldment 1 10 5272287 Battery Wire Assembly 1 11 5272288 Lead Wire Assembly Positive 1 12 5272289 Jumper Wire Assembly 1 13 5272290 Push But...

Page 7: ...Page 7 NOTES ...

Page 8: ...this Limited Warranty you must 1 provide written notice to Fimco Inc of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Inc 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Inc or an authorized dealer within a reasonable period of time For more infor...