23
6
MMA WELDING
6.1 CONNECTING THE ELECTRODE HOLDER AND THE EARTH CABLE
EXTERNAL ACCESSIBLE LIVE PARTS UNDER VOLTAGE (Negative AND Positive Terminal Fast-
Connect Plug).
WARNING OF HIGH VOLTAGE ELECTRIC SHOCK INJURY
NB: the manufacturer indicates polarity on electrodes’ package
NB: special electrode holders and carbon electrodes are necessary for gouging
Installation:
•
Insert the electrode holder’s cable into either the
“ + ”
or
“ - “
welding current socket and lock it by
turning it clockwise.
•
Insert the earth cable’s connector into either the welding
“ + ”
or
“ - “
welding current socket and lock
it by turning it clockwise.
•
Place polarity cable for euro connection socket into
“ 0 ”
rest position.
6.2 WELDING CURRENT MANUAL SELECTION
Select welding current through the “EN1” knob.
6.3 ARC FORCE
Select welding current through the “POT3” knob.
6.4 HOT START
Select welding current through the “POT4” knob.
6.5 ANTISTICKING
Antistick device prevents electrode’s burning.
If the electrode sticks in spite of Arc Force device, then the machine automatically cuts the current in 2
seconds to avoid electrode’s burning.