The anti-seize pump function is a function that will configure the thermostat
as an asymmetrical timer.
By setting a value between 1 and 999 HOURS, the thermostat will close the
output contact for 30 seconds, every time the set time value has elapsed.
Example:
By setting with keys
the value 120 (120 hours = 5 days) and confirming
with
OK
, the thermostat will close the relay contact for 30 seconds, every 5
days.
After enabling the function in the menu, the count will start after the last
switching off of the relay.
5
-
DAYLIGHT SAVING function
This function allows you to set the thermostat such that:
- Daylight saving time changes automatically
- Daylight saving time does not change automatically
- Enables the choice of either Monday or Sunday to be day “1”
The screens appear as follows:
Confirming with
OK
the thermostat will automatically change to daylight
savings time.
With the keys
it is possible to change this value to so that the
daylight saving changeover does not happen automatically.