The thermostat is equipped with two input terminals, A and B, dedicated to
remote control (
see page 37, figure 2
).
You can connect a contact to force the thermostat into the AUTO-ON condition.
The display will show the message
.
It is possible to program two modes of operation:
1) With the LOCK mode enabled without PIN (PIN = 000), it will be possible to
adjust the temperature of the thermostat with the sliders.
2) With the LOCK mode enabled with PIN (PIN other than 000), it will not be
possible to make any adjustment of temperature
NOTE
Cannot be used with external sensor (page 62).
Example: “
landlord
”.
The thermostat can be turned on remotely, when the room is occupied.
It is possible to realize the situations whereby:
1) If you have not previously entered your PIN, the tenant can act on
thermostat and change the sliders to suit his needs
2) If you have previously entered your PIN, the thermostat will follow the
temperature pre-set via the sliders and the user cannot make any changes.
Conversely, the thermostat can be turned off remotely (for example utilizing
a relay contact or a time switch, or other device).
REMOTE CONTROL
61