background image

LIMITED WARRANTY & LIMITATION OF LIABILITY

Fine Instruments Corporation (Finest) warrants this product to be free from defects
in  material  and  workmanship  under  normal  use  and  service  f or  3  years.  This
warranty  extends  only to  the  original  buyer  or  end-user  customer  of  a  Finest
authorized reseller, and is not applied to fuses, battery or to any product which, in
Finest’s option, has been misused, altered, neglected or damaged by accident or
abnormal conditions of operation or handling.
Finest   warrants  that  sof tware  will  operate  on  appropriate  Finest  instruments
substantially in accordance with its functional specifications for 90 days and that it
has been properly recorded on non-defective media. Finest does not warrant that
software will be error free or operate without interruption.

Finest authorized resellers shall extend this warranty on new and unused products
to end-user customers only but have no authority to extend a greater or different
warranty on behalf of Finest.

Finest’s warranty obligation is limited, at Finest’s option, to refund of the purchase
price,  or free  of   charge  repair  or replacement  of  a  defective product  which  is
returned to the Finest’s factory within the warranty period.

To obtain warranty service, contact your nearest Finest authorized reseller or send
the product, with a description of the difficulty, postage and insurance prepaid (FCA
Destination), to the nearest Finest authorized reseller. Finest assumes no risk for
damage in transit. Finishing warranty repair, the product will be returned to Buyer,
transportation prepaid (FCA Destination). If Finest determines that the failure was
caused  by  misuse,  accident ,  abnormal  condit ion  of  operation  /  handing,   or
alteration, Finest will provide an estimate of repair costs and obtain authorization
before commencing the repair work. Finishing repair, the product will be returned to
the  Buyer transportat ion prepaid  and  the  Buyer  will  be  billed  for  the  repair  and
return transportation charges (FCA shipping Point).

Warranty  service  is  available  out side  the  Republic  of  Korea  only  if  product  was
purchased through a Finest Authorized Sales Outlet in the country of use. Finest
reserves the right to invoice Buyer for importation costs of repair/replacement parts
when product purchased in one country is submitted for repair to the Finest factory
in the Republic of Korea.

DISCLAIMER

THIS WARRANTY  IS  IN LIEU  OF ANY  OTHER  WARRANTIES, EXPRESSED OR
IMPLIED,  INCLUDING ANY WARRANTY  OF MERCHANTABILITY OR FITNESS FOR
A  PARTICULAR  PURPOSE. FINEST  SHALL  NOT BE  LIABLE  FOR  ANY  SPECIAL,
I NDIRECT,  I NCIDE NTA L  O R  CONS EQUE NTI AL  DAMA GE S  O R  LO SS ES,
INCLUDING  LOSS OF DATA, WHETHER  ARISING FROM  BREACH OF WARRANTY
OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.

Summary of Contents for 701

Page 1: ...E INSTRUMENTS CORPORATION 341 5 SONGNAE DONG SOSA GU BUCHON SHI KYUNGGI DO KOREA TEL 82 32 656 8771 4 FAX 82 32 656 5844 E mail fine finest co kr Copyright 2001 Fine Instruments Corp All right reserved Specifications subject to change without notice Litho in Korea a world leader in test measurement ...

Page 2: ... AC voltage 0 75 DC Current 0 to 10 A 20 A for 30 seconds AC Current 703 True RMS 20 µA to 10 A 20 A for 30 seconds 701 0 to 10 A 20 A for 30 seconds Resistance 0 to 40 M Capacitance 0 01 nF to 100 µF Frequency 0 5 Hz to 10 MHz Duty Cycle 0 1 to 99 9 for 0 5 Hz to 500 kHz pulse width 2 µsec Diode Test 2 5 V Continuity Check Beep at Approx 10 response time 1 ms Temperature 703 only 40 C to 1300 C 4...

Page 3: ...shock hazard to the user Inspect test leads connectors and probes for damaged insulation or exposed metal before using the meter If any defects are found replace them immediately Do not touch test lead tips or the circuit being tested while power is applied to the circuit under test Always keep your fingers behind the finger guards of the test leads during measurement Do not measure any circuit th...

Page 4: ...fective or equivalent DC value of an AC signal Most digital multimeters use average sensing RMS calibrated technique to measure RMS values of AC signals This technique is to obtain the average value by rectifying and filtering the AC signal The average value is then scaled upward that is calibrated to read the RMS value of a sine wave In measuring pure sinusoidal waveform this technique is fast ac...

Page 5: ...rrent measuring device caused by internal shunt resistance Burden voltage contributes measurement error and should be as low as practical Temperature Coefficient Temperature Coefficient is a factor used to calculate the change in indication or output of an instrument with changes in temperature Uncompensated changes in temperature contribute uncertainty by an amount determined by the temperature c...

Page 6: ...or two seconds to turn the backlight ON or OFF when the HOLD function is simultaneously activated with the D H symbol on the display Press the HOLD button momentarily again to activate the Backlight function only SELECT Press this button to toggle between the dc measurement mode and the ac measurement mode when the rotary selector switch is set to Model 703 only and And also press this button to c...

Page 7: ...age However to prevent accidentally exceeding the protection circuit s rating and to ensure a correct measurement NEVER CONNECT THE LEADS TO A SOURCE OF VOLTAGE when the rotary switch is set to or or functions 11 10 To improve the accuracy of dc voltage measurements taken in the presence of ac voltages such as measuring the dc voltage of an amplifier in the presence of an ac signal measure the ac ...

Page 8: ...indicates a leaky defective diode A zero reading indicates a shorted defective diode An indicates an open diode defective Reverse the test leads connections reverse biased across the diode The display shows if the diode is good Any other readings indicate the diode is shorted or resistive defective Continuity Test The continuity function detects intermittent opens and shorts lasting as little as 1...

Page 9: ...microfarad µF range The available capacitance ranges are 40nF 400 nF 4 µF 40 µF and 100 µF 15 14 Caution To avoid damaging the meter or the equipment under test remove all power from the circuit and discharge all high voltage capacitors before measuring capacitance Large value capacitors should be discharged through an appropriate resistance load Use the dc voltage function to confirm that the cap...

Page 10: ...er defaults at dc Press SELECT button momentarily to select ac To measure dc or ac current 1 Turn off power to the circuit and discharge all high voltage capacitors 2 Insert the black lead into the COM terminal and the red lead into an input terminal appropriate for the measurement range as the following table To avoid blowing the meter s 440 mA fuse use the mAµA terminal only if you are sure the ...

Page 11: ...re it separately Battery and Fuse Replacement The meter uses a single standard 9V battery NEDA 1604 JIS006P IEC 6F 22 a 1000 V 440 mA IR 10 kA fast acting F fuse F71 for mAµA current input and a 1000 V 11A IR 10KA fast acting F fuse F72 for A current input The F71 440 mA F72 11 A fuse must be replaced by qualified service personnel only Trouble Shooting If the meter fails to operate even with the ...

Page 12: ...Humidity 0 to 80 0 C to 35 C 0 to 70 35 C to 40 C Altitude Operating up to 2000m Storage 10000m Battery Type Single 9V battery NEDA 1604 JIS 006P or IEC 6F 22 7 SPECIFICATIONS Battery Life 250 hrs typical with backlight off 703 750 hrs typical with backlight off 701 Shock Vibration Per MIL T PRF 28800 for Class II instruments Pollution Degree 2 Electromagnetic Compatibility EMC Susceptibility Comm...

Page 13: ... 703 Accuracy 400 mV 100 µV 0 5 2 0 5 2 4 V 1 mV 0 75 3 40 V 10 mV 400 V 100 mV 1000 V 1 V 0 75 3 Resolution DC Current AC Current Resistance Open Circuit Voltage 1 3 V dc Range 40 Hz 400 Hz 400 Hz 10 kHz Accuracy 701 703 703 400 µA 0 1 µA 4000 µA 1 µA 1 0 5 40 mA 10 µA 400 mA 100 µA 4 A 1 mA 1 0 5 1 5 10 1 5 10 2 0 10 10 A 10 mA 1 5 5 Resolution Range 701 703 Accuracy 400 µA 4000 µA 1 0 2 40 mA 4...

Page 14: ... µA 4000 µA 40 mA 400 mA 4 A 10 A 150 µV µA 150 µV µA 3 3 mV mA 3 3 mV mA 0 03 V A 0 03 V A 10 A Range Accuracy Open Circuit Voltage 4V 2 Test Current Typical 0 25 mA 1 5 V dc Audible threshold the beeper sounds if the measured resistance is lower than 10 and turns off when greater than about 60 Response time 1 msec Range 701 703 Accuracy 1 2 5 10 2 5 10 40 nF 10 pF 400 nF 100 pF 4 µF 1 nF 40 µF 1...

Page 15: ...st authorized reseller or send the product with a description of the difficulty postage and insurance prepaid FCA Destination to the nearest Finest authorized reseller Finest assumes no risk for damage in transit Finishing warranty repair the product will be returned to Buyer transportation prepaid FCA Destination If Finest determines that the failure was caused by misuse accident abnormal conditi...

Reviews: