4 feet / 1.2 meter
(recommended)
USB Port
Wiegand OUT
RS232
RS232
cable
RS485
485-
485+
GND
TXD
RXD
WD0
WD1
SGND
GND
3rd party controller
with 26 bits Wiegand
input
RX+
RX-
1. RS485 Single Connection
RS232/RS485
Data Converter
RX+
RX-
RS232/RS485
Data
Converter
2. RS485 Network Connection
485+
485-
485+
485-
485+
4851
GND
+12V
DC12V 3A
Power Supply
........
RS485-Wiegand Connection Port
Power Port (B)
TCP/IP Port
Access Control Port
External
Alarm Port
(FMM)
Power Port (A)
Step 1
Determine the Installation Location
•
Avoid installing the terminals in locations that have contact with
strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)
•
Avoid installing the terminals in locations with high moisture or
condensation levels in the air
•
The recommended installation height of the terminal from the
ground to the camera is 1.2 meter.
Step 2
Mount Terminal on a Wall
1. Avoid strong sunlight
2. Install the terminal 1.2m from the ground level (measure the
height from the ground to the face camera)”
After measuring the height accordingly and make relevant markings on
the wall, drill the screws into the wall to secure the back plate.
Attach the terminal to the back plate and tighten the screws.
Refer to Appendix II for dimensions and measurements of installation.
Installation Guide
Face & Fingerprint Recognition System for
Door Access & Time Attendance
Step 3
Wiring for Power Supply
Use the power adapter provided in the package and insert the
power adapter to the Power Port (A).
OR
Use power cables (black and red) to connect to a linear power sup-
ply with specifications of 12VDC 3A to Power Port (B).
© 2017 Timetec Computing Sdn Bhd. All rights reserved.• 032017