background image

Note: 

Press 1 to disable this feature if you do not want to link up H3i 

with an alarm or siren system. 

To turn off alarm output: Verify your Admin password > Press #

 

ENABLE ILLEGAL DISMANTLE ALARM

H3i will trigger the alarm or siren system immediately if 
somebody tries to dismantle it. 

Operation: 

Verify your Admin password > Green LED 

blinks > Buzzer emits long beep > Press 7 > Green LED 
blinks > Buzzer emits long beep > Press 0 > Green LED 
blinks > Buzzer emits long beep > Changes done success-
fully

Note: 

Press 1 to disable this feature if you do not want to use it. 

 

APPLY MULTI VERIFICATION METHOD

You can increase your access control’s security level by 
applying multiple verification methods. 

Operation: 

Verify your Admin password > Press 5 > 

Green LED blinks > Buzzer emits long beep > Insert 
number to represent the type of multi verification (as per 
table shown) > Green LED blinks > Buzzer emits long 
beep > Multi verification applied successfully

NUMBER MULTI 

VERIFICATION 

 1 

Password 

only

 2 

Card 

only

 3 

Fingerprint 

only

 4 

Fingerprint/Card/Password 

 

Card + Password 

 

Finge Password

ENABLE FAIL VERIFICATION ALARM

Enable device to trigger alarm or siren system when a 
user fails to verify more than 3 continuous times. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 2 > 
Green LED blinks > Buzzer emits long beep > Press 0 > 
Green LED blinks > Buzzer emits long beep > Changes 
done successfully

Note: 

Press 1 to disable this feature if you do not want to use it.

5

FINALIZING THE INSTALLATION  

1. Check that all cable connections are done 

correctly. 

2.  Attach the terminal to the corresponding back 

plates and tighten the screws to secure the 
terminal on the wall.

3.  Switch on the power to the terminal.
4.  Start using the terminal.

Diagram1 • Normally Close (NC)

Diagram 3 • Other Accessories

Door Lock Connectors

The terminal will trigger the alarm output (NO or NC) 
for the following situations:
• Door forced open (a door sensor must first be 

installed)

• Door open time out (a door sensor must first be 

installed)

• Terminal has been illegally dismantled

APPENDIX  • TERMINAL DIMENSIONS AND MEASUREMENTS 

DC12V 3A 

Power Supply

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

Door sensor

EM Lock (NC)

---
+

Emergency Break 2

Glass (Type NC)

3

Override Switch 

A

(Type NC)

C

Release button

DOOR LOCK ACCESSORIES

 

FingerTec offers various door lock accessories to 
complement FingerTec door access products. For 
more info, go to 

http://accessory.fingertec.com

.

APPENDIX  • POWER SUPPLY & DOOR LOCK SYSTEM WIRING DIAGRAMS   

Diagram 2 • Normally Open (NO)  

DC12V 3A 

Power Supply

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

Door sensor

EM Lock (NO)

---
+

Emergency Break 1

Glass (Type NO) 3

Override Switch

B

(Type NO)

D

Release button

DC12V 3A 

Power Supply

Door Sensor

Alarm device Type NO 

or NC Dry contact

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

WIRING PORT

NO

NC

COM

SEN

GND

BUT

AL+

AL-

USAGE

Dry Contact

 

(Independent power supply for door lock)

• NO type door lock (NO-COM)
• NC type door lock (NC-COM)

Power Contact

 

(Using power from terminal to power on door lock)

• NO type door lock (NO-GND)
• NC type door lock (NC-GND)

Dry Contact

 

(Independent power supply for door lock)

• NO type door lock (NO-COM)
• NC type door lock (NC-COM)

Power contact 

(Using power from terminal to power on door lock)

• COM1 - +12V

Door Sensor

 (SEN-GND)

Release Button 

(BUT-GND)

Alarm System 

NO or NC Type – Check in Advance Options

©

2013

 

FingerTec Worldwide Sdn. Bhd. All rights reserved • 062013

84 mm

84 mm

38 mm

38 mm

38 mm

38 mm

32 mm

10 mm

10mm

10mm

7mm

3mm

Front View of Terminal Back Plate