MEGA SD - Cod.197DD8100
GB
START-Up AND OpERATION
c)
prepare to start with the following message
In this case, the remote control function has been enabled (see
paragraph 4.2.3):
The compressor will start when the remote command is received.
d)
prepare to start with the following message
In this case, the daily or weekly programming function has been
enabled and the compressor is in the OFF programming phase
(see paragraph 4.2.6). The compressor starts when an ON
programming phase is initiated.
The following contacts will be made in sequence:
Stand- by rem. com.
hour-date
Stand by progr. com.
hour-date
Start
hour-date
Start
hour-date
Load run
hour-date
unload run
hour-date
unload run
hour-date 04m 59s
Stand by auto start
hour-date
unload run
hour-date
LINE - STAR – DELTA
and one of the two messages will be displayed
when the display shows
“Load run”
the intake valve is open and the machine operates
at full load (produces the nominal capacity of compressed air).
During functioning, delivery pressure increases; once the preset maximum line pressure
threshold value has been reached, the control system sets the compressor to idling
by closing the intake valve
“Unload run”
. when the pressure drops below the preset
minimum threshold value, the intake valve opens again and the machine restarts
functioning at full load.
During unload run, two cases may arise:
a)
Setting of AuTOMATIC functioning (see paragraph 4.2.3):
The compressor outputs this message followed by a countdown.
At the end of the countdown, the compressor switches off, changing to”Stand-by
auto start”, status, ready to restart in the case of a request for air.
b)
Setting of CONTIN. functioning (see paragraph 4.2.3):
The compressor outputs the “unload run message, the machine never stops,
always remaining available to restart production of compressed air immediately
in the case of any request.