2.2 STORAGE
S
C
C
0
0
0
1
Even when packaged, keep the machine
protected from severity of the weather.
Keep the dryer in vertical position, also when
stored. Turning it upside down some parts could
be irreparably damaged.
If not in use, the dryer can be stored in its
packaging in a dust free and protected site at a
maximum temperature of 45 °C, and a specific
humidity not exceeding 90%. Should the
stocking time exceed 12 months, please contact
the manufacturer.
The packaging materials are recyclable. Dispose of material in compliance with the rules
and regulations in force in the destination country.
2.3 INSTALLATION SITE
Failure to install dryer in the proper ambient conditions will affect the dryer’s ability to condense
refrigerant gas. This can cause higher loads on the compressor, loss of dryer efficiency and
performance, overheated condenser fan motors, electrical component failure and dryer failure due
to the following: compressor loss, fan motor failure and electrical component failure. Failures of
this type will affect warranty considerations.
Do not install dryer in an environment of corrosive chemicals, explosive gasses, poisonous
gasses; steam heat, areas of high ambient conditions or extreme dust and dirt.
In case of fire, use an approved fire
extinguisher, water is not an acceptable
means in cases of fire.
Minimal installation requirements :
•
Select a clean dry area, free from dust, and
protected from atmospheric disturbances.
•
The supporting area must be smooth, horizontal
and able to hold the weight of the dryer.
•
Minimum ambient tempe1 °C.
•
Maximum ambient tempe45°C.
•
Allow at least a clearance of 1 m on each side of
the dryer (2 m RD 480-810 dryers, Air-Cooled
models), for proper ventilation and to facilitate
eventual maintenance operations.
The dryer doesn't require to be fixed to the
supporting surface. The dryer needs to be fixed to
the supporting surface only with particular installation
procedures (dryer on brackets, hanging units, etc.)
2 m
(480-81
0)
1 m
1
m
(4
8
0
-8
1
0
)
2
m
1 m
1 m
L
G
T
0
0
0
3
Summary of Contents for RD 185-810
Page 39: ...40069 Zola Predosa BO ITALY info finicompressors it 7 1 7 RD 480 620 WC 7 1 8 RD 810 WC ...
Page 40: ...40069 Zola Predosa BO ITALY info finicompressors it 7 2 1 RD 185 410 ...
Page 41: ...40069 Zola Predosa BO ITALY info finicompressors it 7 2 2 RD 480 810 ...
Page 54: ...40069 Zola Predosa BO ITALY info finicompressors it The access code to the 2 level is 20 EN ...