R600a (ISOBUTANE)

Isobutane is a natural gas that doesn’t affect the environment, but it is inflammable. Before con-

necting the equipment to the mains, it is therefore indispensable to check that the cooling circuit

tubing is not damaged. For every 8 grams of cooling fluid, there must be a minimum of 1 cubic metre of

space in the room where the appliance is installed. In the event of a leakage of cooling fluid, make sure

that no flames or other sources of ignition are allowed to get near the leakage point.

INSTALLATION

The equipment must be installed by two people in order to avoid damage to persons and

things. If the equipment has suffered damage

during transport, immediately inform the supplier before

connecting up. Wait at least two hours after installation

before putting the appliance into operation, to allow the

cooling fluid to reach optimum efficiency. The equip-

ment must be put in a dry, well ventilated place. It must

be installed on a flat, stable surface. Adjust the levelling

feet if necessary. There must be at least 90 mm space be-

tween the back of the equipment and the wall (Fig. 1).

Any shelving or cupboards over the appliance must be at

least 800 mm from the cover. Ambient temperature con-

siderably affects energy consumption, so the equipment

shouldn’t be exposed to direct sunlight or placed next to

heat sources such as heaters, stoves, cookers, etc. Check

the climate classification on technical data plate on the

back of the equipment.

''

SN 

''

 (operates at ambient temperatures between) +10° C and +32° C

''

''

 (operates at ambient temperatures between) +16° C and +32° C

''

ST 

''

 (operates at ambient temperatures between) +16° C and +38° C

''

''

 (operates at ambient temperatures between) +16° C and +43° C

Important:

Make sure there is easy access to the power outlet so that the plug can be removed when necessary. If this

isn’t possible, connect the equipment to the mains by means of a bipolar switch, in an accessible position,

with a contact opening of at least 3 mm.

ELECTRICAL CONNECTION

Connection of the equipment to a power outlet with an earth contact is a legal requirement. For this

reason the equipment is fitted with a plug with an earth wire for connection to an outlet of the same

type. The manufacturer declines any liability for damage to persons, property or pets due to failure

to observe this rule.

 Check that the voltage indicated on the technical data plate on the back of the

equipment is the same as that of your mains supply.

How to replace the lamp (only for appliances with lamp) Unplug the equipment or switch off at the main

power switch before replacing the lamp. Only use lamps of the wattage indicated on the lamp shield

(eg. max. 15 W).

9  cm

20  cm

 (Fig. 1).

Summary of Contents for FR-CF100DA+W

Page 1: ...FREEZER FR CF200DA W FR CF250DA W FR CF300DA W FR CF400DA W Instrukcja obs ugi i konserwacji Instructions for use and maintenance ZAMRA ARKA SKRZYNIOWA CHEST FREEZER FR CF100DA W FR CF150DA W FR CF200...

Page 2: ......

Page 3: ...nale y umieszcza butelek ani innych szklanych pojemnik w w komorze o niskiej temperaturze poniewa mog pop ka lub zosta uszkodzone po zamro eniu ich zawarto ci Nie wolno spo ywa produkt w kt rych termi...

Page 4: ...egatywnie na rodowisko ale jest atwopalny Przed pod czeniem urz dzenia do sieci elektrycznej nale y koniecznie sprawdzi czy orurowanie uk adu ch odniczego nie jest uszkodzone W pomieszczeniu w kt rym...

Page 5: ...aturze nie wolno przechowywa szklanych pojemnik w z ciep ymi p ynami Wa ne Nie wolno spo ywa kostek lodu ani lod w na patyku bezpo rednio wyj tych z zamra arki poniewa spowoduj poparzenie lodem POWER...

Page 6: ...yby one nieodwracalnie uszkodzi uk ad ch odniczy i sta si r d em zagro enia w urz dzeniu z czynnikiem ch odz cym R600a Zalecamy odszranianie gdy komora jest pusta lub zawiera tylko kilka artyku w spo...

Page 7: ...w cz ci zatytu owanej WA NE OSTRZE ENIA DOTYCZ CE BEZPIECZE STWA Je li zamra arka nadal nie dzia a prawid owo po przeprowadzeniu czynno ci opisanych powy ej skontaktuj si z najbli szym CENTRUM OBS UG...

Page 8: ......

Page 9: ...w temperature compartment and they may crack or break when their contents are frozen Don t eat food whose eat by date has expired as this may lead to food poisoning Don t obstruct any of the opening v...

Page 10: ...energy consumption so the equipment shouldn t be exposed to direct sunlight or placed next to heat sources such as heaters stoves cookers etc Check the climate classification on technical data plate o...

Page 11: ...i r o s s e r p m o c t a h t s e t a c i d n i R O S S E R P M O C D E L n e e r g You can keep frozen food for some months in the low temperature compartment 18 under freezing function or you can ad...

Page 12: ...th water and dry care fully Never use a steam cleaner to defrost or clean the equipment Steam can damage live parts in the equipment and produce a short circuit and or electric shock Steam also damage...

Page 13: ...ANT SAFETY WARNINGS If the freezer still won t work properly after carrying out the procedures described above call the nearest CUSTOMER SERVICE indicated on attached slip Important the freezer may pr...

Page 14: ...FR CF100DA W FR CF150DA W FR CF200DA W CHEST FREEZER CABINET DIMENSIONS...

Page 15: ...FR CF250DA W FR CF300DA W FR CF400DA W...

Page 16: ......

Reviews: