C- INSTALLATION INSTRUCTIONS  

Prior to carrying out maintenance operations, ensure that the safety precautions specified in Article A and B have been taken.  

Ensure that istallation is carried out by the authorized service provider. Take into consideration the model verions, series and installation figures 

given in page 10 as well as the following instructions for the installation process.  

For the fume hood;

* Drill holes on the points marked on the device and safely fix the device body on the wall using the fixing pulgs and screws that come in the product 

package.  

* Fix the provided flue support plates to the wall using the fixing plugs and screws. Connect the flue to the device body.  

* Connect a flexible pipe of appropriate diameter (150 mm preferred) and length to be provided by the user to the reducing flap flue (120 to 150 mm 

of diameter) and ensure that the other end goes outside.  
* To avoid vibration and suction noise, ensure that the pipe is leakage-free, its connection is appropriate and it does not move.  

* Fix the flues using screws after carrying out the power connection and the operation test.  

For the ventilation hood;

* Drill the holes as shown in Figure G1 and G2 inside your closet according to the template provided with the product.  

* Place the device inside the closet and fix it using the m4x40 screws that come with the device.  

* Connect the 100 mm flexible pipe provided by the user to the the flue flap and ensure air discharge. 

A-GENERAL INFORMATION 

Dear Customers,

Please read the user’s manual for safe mounting and maintenance and keep it in an accessible location for easy urgent acces. This manual was 

prepared for more than one device. Refer to Seciton H - Coding for your device’s model.  

Flap flues, flue supporting plate, fixing plugs and screws are provided inside the product package in different sizes and dimensions for each 

product. Please check the package for them.  

* This product is not for industrial use; it is for domestic use.  

* Installation of our products will be carried out by our authorized service providers in a controlled and supervised manner.   

* We cannot be held responsible for damages arising from inappropriate installation of the product by incompetent persons who are not part of our 

authorized service.  

* Keep and maintain the product package throughout the product’s warranty period.  

* As required for our constant development policy; we reserve the right to carry out modifications and corrections on our products without prior 

notice. We hold the sole responsibility for all of our revised products.  

* The life of service for our products is 10 years. Note that this life of service is valid only if the user fully complies with the instructions provided in 

the user’s manual.  

B-SECURITY INSTRUCTIONS

* Check the product’s power diagram to make sure that the device’^s power and current requirements are appropriate for your power circuit. In case 

you experience a problem, consult an competent electrician. Do not install the device in case of inappropriate circumstances.  

* You need a earthed plug for your device. Ensure that your plug is earthed.  

* Do not carry out maintenance operations while your fume hood is on.  

* Do not touch the light bulbs or their surrounding area when the lighting is on or has been used for a long time.  

* Do not cook on high temperatures while your fume hood is operating.  

* Check your food regularly in case a fire might break out due to hot oil when frying food.  

* This device is not appropriate for use by children or adults who require supervision. 

* In case the device is not cleaned in accordance with cleaning instructions, risk of fire will be present. Do not neglect cleaning the device.  

* Ensure, at al times, that there is a vertical distance of 65 cm between the middle suction area of the fume hood and the top point of the cooker.  

* Do not connect ventilation devices evacuating warm air or smoke and the air evacuation output of the fume hood in the same area.  

* If a flue connection is to be established; have your flue checked to ensure that it is clean, unobstructed, recoilles and problem-free.  

* If you are using carbon filters on your product, replace the carbon filter in every 3 to 6 months in accordance with your frequency of use.  

* Comply with local regulations for evacuation of air.  

*This appliance is not manufactured for use by people who have disability about physical, sense and mental ability (including children) or people who 

lack experience and knowledge without supervision or management  of the person who responsible about safety of this appliance.

*Keep children under supervision to ensure, they do not play with the appliance.

*Appliance can use by 8 years old and older children and people with reduced physical,sense and mental ability or people who lack experience and 

knowledge with  under supervision or use the appliance safely and introduction is given for understanding of the dangerous. Children do not play 

with appliance.

*Cleaning or user maintenance can not be done by children are older then 8 years old and without supervising.

*If you will use cooker hood with appliences that are used with gas or other fuels, ventilation should be enough.

*Do not blow air in to the appliance that are used with gas or other fuels in order to expel smoke.

Summary of Contents for OPERA CL11-60X

Page 1: ...очетете внимателно всички раздели на това ръководство преди да използвате вашия продукт и да го съхранявате инструкцията впоследствие DEAR OUR CUSTOMER We hope that this product which was manufactured in environment friendly and modern facilities and released after strict quality control offers you the highest level of efficiency We suggest that you carefully read all sections of this manual befor...

Page 2: ...H кодиране за модела на вашето устройство Аксесоари за прикрепване дюбели и винтове са осигурени в опаковката на продукта в различни размери за всеки продукт Моля проверете пакета за тях Този продукт не е за промишлена употреба той е за домашна употреба Монтаж на нашите продукти ще се извършва от наши оторизирани представители и по контролиран начин Ние не може да носим отговорност за вреди произт...

Page 3: ...етствие с продуктовата серия и видове за да се отстранят петролни частици във въздуха и миризма в специални случаи Филтрите с активен въглен трябва да бъдат заменяни на всеки 3 до 6 месеца в съответствие с котлона и системите за готвене ТТехническия раздел F Видове регулатори и употребата им Видовете регулатори които се променят в зависимост от модела на вашия продукт са описани по долу Видът на р...

Page 4: ...nsibility for all of our revised products The life of service for our products is 10 years Note that this life of service is valid only if the user fully complies with the instructions provided in the user s manual B SECURITY INSTRUCTIONS Check the product s power diagram to make sure that the device s power and current requirements are appropriate for your power circuit In case you experience a p...

Page 5: ...cuate oil particles in the air and odour in special cases where the indoor air cannot be evacuated Carbon filters should be replaced in every 3 to 6 months in accordance with stove and cooking systems Type YKF A AC C E After locating the carbon filter on the lugs at both sides of the plastic engine body turn it 90 a quarter turn and the assembly will be completed when you hear the click sound Retr...

Page 6: ...MONTAGE J TECHNICAL SECTION FILTERS Type YALF YKAF A Aluminum filter Figür A Model Serial CL Figür F Type YKF B F mounting Type YKF B ...

Page 7: ...къв вид отпадъци особено електрически и електронни в определената за това точка Разделното събиране и рециклиране на това оборудване допринася за опазване на природните ресурси и гарантира рециклирането им с оглед опазване на околната среда и здравето За по подробна информация относно реда на изхвърляне на електрически и електронни отпадъци следва да се обърнете към местните компетентни власти слу...

Page 8: ......

Reviews: