background image

FINO VITESSE SF

50862

Original FINO

Germany

Mikromotor
Micromotor
Micromoteur
Micromotor
Micromotore
Micromotor
Mikromotor
Mikrosilnik

Gebrauchsinformation•User Information•Mode d’emploi
I n f o r m a c i ó n   s o b r e   e l   u s o • I n f o r m a z i o n i   d ’ u s o
G e b r u i k s a a n w i j z i n g • I n s t r u k c j a   s t o s o w a n i a

FINO

•der feine Unterschied•the fine difference•la fine différence•la fina diferencia•la fine differenza

Summary of Contents for 50862

Page 1: ...omotor Mikromotor Mikrosilnik Gebrauchsinformation User Information Mode d emploi Informaci n sobre el uso Informazioni d uso G e b r u i k s a a n w i j z i n g I n s t r u k c j a s t o s o w a n i...

Page 2: ...Maintenance and cleaning 5 Removal of chuck Separation of crank and motor Change of motor cable Adjustment of magnetic sensor of knee control plate Testing of individual components Replacement of uni...

Page 3: ...sure it corresponds with your mains supply 3 1 Assembly 3 1 1 Tabletop unit Danger of stumbling Install all cables in a way that they do not cause any occupational hazard Place the con trol unit on an...

Page 4: ...oustic signal By actua ting the previously used control device afresh the speed can again be changed 4 1 2 Handpiece 4 1 2 1 Opening of chuck When the chuck is open the motor is blocked To prevent dam...

Page 5: ...the case push the hand foot switch 12 Simultaneously the control light next to the motor switch 14 glows Select the direction of rotation of the motor by pushing the direction selector 13 Now you can...

Page 6: ...l plate The speed is leadlessly controlled through a magne tic sensor on the knee control plate It may happen that the sensor must be adjusted from time to time Switch the control unit off Press the h...

Page 7: ...nit Maintenance tools Test drill 9 Guarantee Our technical recommendations of application are based on our own experiences and tests and should only be regarded as guidelines It rests with the skills...

Page 8: ...The unit was operated under overload conditions 2 The motor cable resp the power cable is damaged 4E Over voltage protection error 1 The control unit is damaged 2 The power supply is interrupted 5E O...

Page 9: ...s to thin Help Switch the unit on by pressing the on off switch 16 Connect the power supply cable properly Replace fuses Connect the motor cable properly If the error is still displayed replace the mo...

Page 10: ...document itself without prior notice FINO does not undertake any guarantee for the completeness or correctness of the contents of this document 7 10 FINO TC Cutters Shank 2 35 mm ISO 104 Recommended...