MNL004_EN rev. F
Pag.
8
di
56
-
Electrical power: the machine has been designed, built and fitted with the aim of preventing risks of electric shock,
in compliance with established safety regulations.
-
Noise: the machine has been designed and built to minimise risks related to the emission of acoustic noise (always
lower than 70 dB).
The following is strictly forbidden:
-
Tampering with or removing the evaporator cover enclosure that protects the user from a risk of cutting on the
evaporator fins
-
Removal of the data plates fixed in the inside edge of the motor compartment that contain technical specifications
and earth connection warnings
-
Removal of the data plate fixed on the evaporator unit guard and near the electrical wiring inside the motor
compartment, which warns the user to disconnect power before working on the unit.
The manufacturer declines any responsibility for safety of the machine if the above recommendations
are not observed.
2.3
CONTRAINDICATIONS
The refrigerated cabinet must not be used:
-
exposed to weathering
-
With adapters or extension cords
-
In explosive atmospheres or where there is a risk of fire
-
Near to heat sources (radiators, etc.)
-
2.4
WARNING ON THE REFRIGERANT GAS
If in the device a flammable gas is used like R290 refrigerant, the following label appears on the compressor.
In this case, some special precautions should be taken:
- position the appliance in an environment of suitable dimensions in compliance with EN 378: the environment must
have a volume of 1m
3
every 8gr of R290 refrigerant. The quantity of gas contained in the circuit is declared on the silver
data plate attached inside the cabinet.
- do not use the equipment if damaged.
- to avoid damages to the refrigerant circuit, do not use mechanical devices to accelerate defrost process.
- make sure that air grids are always free to guarantee a certain ventilation to the device.
- if there is refrigerant leakage, avoid using open flames, remove from the device flammable products and ventilate
immediately the environment.
- do not store potential explosive substances (for example spray cans containing flammable gases) inside the device.
Do not use electrical appliances inside the refrigerated cabinet.
If any malfunction, disconnect the equipment from the mains.
Extraordinary maintenance should be performed only by qualified personnel.