42
14
DRAWBACKS AND REMEDIES
The following table provides guidance in identifying the causes and solve the most frequent
anomalies, which do not allow technical service.
Electrical repairs may be also performed by your electrician.
Before contacting Technical Service, make sure you tried all the recommended
checks for user.
DRAWBACK
POSSIBLE CAUSE
SOLUTION
The equipment does
not turn on
Controller Stand-by
Switch the controller on,
Par. 5.2.1
No mains
Check power supply
Power supply not plugged in
Check plug, socket, fuses
and power line
Faulty control panel
Contact service
Other
Contact service
Equipment does not
reach set temperature
Too many products have been
filled in the chamber.
Or
Too humid material in the
compartment
Or
Material at room temperature
(+25°C) in freezer
compartment
Once the temperature inside
the chamber has stabilized,
fill the products little by little.
Reduce the quantity of
products and keep distance
from shelves and walls.
The freezer has been
designed for storage of
products; it is suggested to
fill in products gradually and
in small quantities.
Too long and too frequent
door openings.
Reduce the number of door
openings; close the door as
soon as possible.
Too high ambient temperature
Cool down the ambient.
Condenser clogged by dirt and
dust
Clean condenser Par. 8.3
Controller is not functioning
properly
Contact service
Cooling system is not
functioning properly
Contact service
Summary of Contents for ECT-F TOUCH
Page 1: ...USER AND MAINTENANCE Manual ECT F TOUCH ...
Page 2: ......
Page 55: ......
Page 56: ...56 MNL066_ENG Rev B ...