TIME DEFROST
Tap on icon
in order to
view alarm list and to mute it
(par.5.2.16)
Turn the refrigerator off from
the display, -STAND BY-
Par.5.2.8 and turn it back on
after a few seconds.
If the problem occurs again
after the following defrost
cycle, contact technical
service.
Too many products have been
filled in the chamber.
Too humid products
Freezer cabinets: Ambient
temperature < +10° C
or
Too high ambient temperature
Faulty defrost heater or solenoid
valve
Electrical or electronic faults
HIGH CONDENSING
TEMPERATURE
Clean condenser, Par. 8.3
Cool down the ambient.
Turn the refrigerator off from
the display, -STAND BY-
Par.5.2.8. After a while turn it
on and the visual and
acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
Condenser clogged with dirt and
dust
Too high ambient temperature
Faulty condenser fan motor
Faulty electronic board relays
If the problem occurs again,
contact technical service
COMPRESSO WORK
Clean condenser, Par. 8.3
Cool down the ambient.
Turn the refrigerator off from
the display, -STAND BY-
Par.5.2.8. After a while turn it
on and the visual and
acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
If the problem occurs again,
contact technical service
Condenser clogged with dirt and
dust
Hot ambient temperature
Continuous working of
compressor for 24hours
Leakage in cooling equipment.
Wrong use of equipment, i.e. too
many door openings