52
PROTECTION
AGAINST
OVERHEATING
Turn the refrigerator off from
the diplay, -STAND BY-
Par.5.2.8. Disconnect and
reconnect to mains. After a
while turn it on and the visual
and acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
Device functioning is still
guaranteed, while waiting for
service.
Contact technical service
Faulty Relay U2 or electrical parts
Unbalanced probes
PROTECTION
AGAINST FREEZING
Turn the refrigerator off from
the diplay, -STAND BY-
Par.5.2.8. Disconnect and
reconnect to mains. After a
while turn it on and the visual
and acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
Device functioning is still
guaranteed, while waiting for
service.
Contact technical service
Faulty Relay U2 or electrical parts
Unbalanced probes
FAILURE LOAD U1
COMPRESSOR
RELAY AUX
FAILURE
If this alarm is an isolated
occurrence, the device
continues working but the
protection against freezing
may not be active.
If this alarm is combined with
temperature alarms, it is
necessary to contact
immediately technical service
for board replacement.
Tap on icon
in order to
view alarm list and to mute it
(par.5.2.16)
Turn the refrigerator off from
the diplay, -STAND BY-
Par.5.2.8 and turn it on after
a few seconds.
If the alarm occurs again,
Contact technical service
U1 and 1 AUX: Reporting of
abnormal absorption or false
alarm relay (Compressor)
Faulty Relay