53
FAILURE LOAD U2
FAILURE LOAD U3
FAILURE LOAD U4
FAILURE LOAD U5
FAILURE LOAD U6
DEFROST RELAY
AUX FAILURE
Turn the refrigerator off from
the diplay, -STAND BY-
Par.5.2.8. After a while turn it
on and the visual and
acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
Device functioning is still
guaranteed, but not all the
functions are available
Contact technical service
U2 and 2 AUX: Reporting of
abnormal absorption or false
alarm relay (Defrost heater)
U3: Reporting of abnormal
absorption or false alarm relay
(Evaporator fan)
U4: Reporting of abnormal
absorption or false alarm relay
(Fan Condenser)
U5: Reporting of abnormal
absorption or false alarm relay
(heater)
U6: Reporting of abnormal
absorption or false alarm relay
(heater)
ZERO CROSSING
In case of “Zero Crossing
alarm”, the device operation
takes place regularly, but the
compressor relay is not
managed optimally.
Tap on icon
in order to
view alarm list and to mute it
(par.5.2.16)
In case of frequency different
from 50hz, energy
consumption may show
abnormalities.
220V or 115V mains is not stable
and registers spikes dangerous
for electronics.
Faulty electric or electrical parts
AUXILIARY COOLING
SYSTEM FAILURE
(Only TWIN models)
Turn the refrigerator off from
the diplay, -STAND BY-
Par.5.2.8. After a while turn it
on and the visual and
acoustic alarm is off.
Tap the off alarm/fault icon so
to permanently delete the
signal (par.5.2.16).
If the problem occurs again,
contact technical service
One out of two cooling units
failure
Auxiliary unit guarantees regoular
functioning