CLIENT’S RESPONSIBILITIES
The customer is required to:
- do the electrical connection of the appliance
- prepare the place of installation
- provide cleaning products
- perform ordinary maintenance
In case of power failure or malfunctions, do not open the door in order to maintain uniform
temperature inside the cabinet. If the problem persists for many hours, we suggest moving
the stored products in a more suitable place.
1.5
INSTRUCTIONS FOR SERVICE REQUESTS
For any technical problem and service requests, refer exclusively to your local dealer (see
space in the last page) or directly to the manufacturer, specifying model and serial number of
the equipment. Please, send equipment backup data of the last period of functioning as well.
2
DESCRIPTION OF THE PRODUCT
2.1
TECHNICAL DESCRIPTION
The refrigeration of the internal cabinet is the result of low-pressure steaming of a refrigerant
liquid, type HCFC or HFC, in a thermal exchanger (evaporator). The obtained steam is
brought to the original liquid state through a mechanical compression at higher pressure
(compressor), followed by a cooling stage in another thermal exchanger (condenser).
One or more electro-mechanical fans (according to the model) grant the correct and uniform
distribution of the cold air into the chamber.
The appliance consists of a modular single structure coated with various materials and
insulated in expanded polyurethane foam, density 43 Kg/m³.
The controller is in the front panel. In some models, the user can find behind the front panel
the cooling unit represented by the condenser and the electrical loom.
The cabinet of the appliance is fitted with suitable racks for wire shelves, extractible drawers
and wire baskets. The doors are fitted with an automatic device and magnetic seal elements
easily replaceable. During the design and construction stages, the engineers have adopted
all the necessary measures to manufacture equipment compliant to specific safety
requirements such as the internal corners rounded off, the external exhaust of the
condensate liquid, lack of rough surface, fixed guards protecting moving or potentially
dangerous parts, etc. The maximum grids or drawers load for any Fiocchetti model is 30 kg,
and the weight should be uniformly distributed.
Our equipment has been developed for indoor use and it is not meant to be used