MAINTENANCE
I115SS
Rev. 001
22/12/2014
42/58
4.7.11
SWEEPING UNIT SUCTION FILTER AND FILTER SHAKING MOTOR REPLACEMENT
Before carrying out these operations remove the key from the dashboard;
open the machine front guard (figure 4.35)
lift the box lid (figure 4.36)
loosen the two hex screws and remove the frame (detail 1 figure 4.37)
remove the filter shaking motor support (detail 2 figure 4.37)
unplug the filter shaking motor connector;
lift and replace the damaged or clogged filter (detail 3 figure 4.37)
now reverse the order of the above operations
FIGURE 4.35
FIGURE 4.36
1
2
FIGURE 4.37
3