K1000
25
The pump can (by low pressure) suck and mix detergents and other liquid
chemicals thanks to an automatic device which can be controlled remotely with
the head 4F.
Select the low pressure with the head 4F in order to suck automatically detergent
or other liquid additives. When you want to stop drawing up detergent, put the
pump back onto high pressure with the head 4F.
Phases of using head 4F:
Selecting the low and high pressure (whose passage from one to the other
must be made strictly with the gun closed) (1):
1
high pressure (arrow op.) (3);
2
low pressure (arrow op.) (2).
Head cleaning:
3
1.Switch the machine off and disconnect plug from socket
2.Turn off the water supply tap
3.Open the spray gun and hold it open for a couple of seconds so that the
water in the line drains out
4.Take the lance off the trigger gun
5.Put the pin into the nozzle to remove dirt from the head and rinse
Adjusting the jet
:
pos.
“concentrated” (4);
pos.
“fan” (5).
4
5
Phases of using the Kit gun safety catch:
Safe release (1);
Safe locking (2).
1
2