18
temperature increases more than 10/12 °C compared to the outside temperature, the
batteries can be overcharged.
OFF DUTY OR INACTIVE BATTERIES
Inactive batteries looses their automatically their charge. If batteries do not
continually work, the operator has to:
Ø
Charge the batteries once a month with a final stream intensity until gas is
spread and the batteries voltage and weight are constant for 3-4 hours. This
operation has to be done even if the absolute weight is high;
Ø
Keep the batteries in a dry room.
BATTERIES TECHNICAL FEATURES
BATTERY CHARGER TECHNICAL FEATURES
This battery charger can also charge batteries of a different brand.
BATTERIES DISPOSAL
Old batteries are toxic wastes and they have to be thrown in a suitable and authorized
place for the batteries disposal. For a short storage, old batteries must be located in an
authorized room. Moreover, they must be stored in sealed plastic tanks, whose
capacity is not lower than the electrolyte.
SQUEEGEE BLADES REPLACEMENT
Squeegee blades must be replaced when their hedge is worn. A perfect hedge in the
blade allows a perfect dry (picture 13).
Follow these instructions to replace the squeegee blades:
1.
Remove the squeegee from the machine and lay it on a table;
IN
V 230, Hz 50, A5
OUT
V 36, A 30
TENSION
V 6
CAPACITAY
240 A/h
PWEIGHT
28 Kg
DIMENSIONS (LxLxH)
240 x 180
h 280