background image

4

Ins tallation

When installed, the distance between hood and burners must be not
less than 65 cm. above electric burners or 75cm above gas or
 mixed- fuel burners

Electric connection

Before completing any connection, make sure the house voltage
 corresponds with the voltage indicated onthe label affixed inside
the hood. It is advisable to call a qualifed technician to make the
electrical connection

Appliance fitted with plug.

Connect it to a socket which conforms with current regulations.

Electronic control panel

1-

Motor OFF button

2-

On button and motor speed selection button 1

- 2 - 3 - 1 - 2 - . . . .

3-

Speed 1 LED

4-

Speed 2 LED and metal grease filter  saturation
LED (in the latter case, the LED will flash - See
instructions on grease filter cleaning).

5-

Speed 3 LED and carbon filter saturation LED
(in this latter case, the LED will flash - See
instructions on active carbon filter 
replacement).

Warning!

The active carbon filter saturation LED is not activated

In order to activate the carbon filter saturation indicator
press buttons 2 and 7 simultaneously for 3 seconds.
Initially, only LED 4 will flash, then after the 3 seconds have
passed, LED 5 will also start flashing, indicating that the

1

2 3 4

5 6 7

8

9

The exhausting pipe is not supplied and must be purchased apart.

The manufacturer only recommends the use of smooth bore

ducting. As this does not restrict air flow during use.

Do not tile or grout or silicone the appliance to the wall. Suface 

mounting only.

Do not fix the chimeny flue to furniture or shelves unless the

chimney flue can be easily removed in case maintenence is

ever required. 

USE

The cooker hood is provided with an upper air exit, B- for

discharging fumes externally for models including chimney

flue C- (Suction version  A- exhaust pipe 13A not supplied)

In the instance where it is not possible to discharge cooking

fumes and vapours externally even if utilising the model with 

chimney flue. C- the cooker hood may be used in the filter

version F- by mounting two active carbon filters E- the fumes 

and vapours are the recycled via the upper grill G- (depending

on the model the grill may be directly plcaed on the chimney

flue or via the mounting of two small grills      if in possesion

of a model with grill placed on chimney flue the two H exten

-sions  must be placed on the deflector 13F The models provided

with small dome D may only be used in the filter version F

The models without suction motor operate only in the suction 

version and must be connected to a peripheral suction unit (not

supplied)

Operation

The cooker hood is provided with a key or pushbutton control 

panel situated of the frontal part of the cooker hood type in 

possession. for proper operation consult the text below and the

relative illustration:

a. ON/OFF lighting  b. OFF motors

c-d-e. Minimum suction power (c) medium (d) maximum

 (e)

(f) Operation warning light (where present)

carbon filter saturation control system is active. To switch

off the system, re-press the same two buttons after 3

seconds LED 5 will stop fladhing and the device will be 

switched off

6- Intensive speed LED

7- Intensive speed ON switch. This speed should be used

when the concertration of cooking fumes or odours is

particularly strong (for when frying , cooking fish etc).

The fast speed will run for about for about 5 minutes and then

return to the speed previously set automatically (1, 2 or 3),

or switch off the fast speed before the end of the 5 minutes,

press button 1 or button 2 (see page 13 ).

8 - OFF lamp button

9 - ON lamp button

If the hood fails to operate correctly, briefly disconnect it from

it from the mains supply for almost 5 sec .by pulling out the plug.

Then plug it in again  and try once more before contacting

the Technical Assistance

Consult the designs in the front pages referenced in the text by

alaphet letters. Closely follow the instructions set out in this 

manual. All responsibility for any eventual inconviences

damages or fires caused by not complying with the instructions

in the manual is declined.

Use the high suction speed in cases of concentrated kitchen

vapours. It is recommended that the cooker hood suction is 

switched on for 5 minutes prior to cooking and to leave in

operation  during cooking and for another 15 minutes approx-

imatley after terminating cooking.

Summary of Contents for E81 AQUA

Page 1: ...Model E81 AQUA Model E83 KEYLINE CANOPY HOODS ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...nding on the model the grill may be directly plcaed on the chimney flue or via the mounting of two small grills if in possesion of a model with grill placed on chimney flue the two H exten sions must be placed on the deflector 13F The models provided with small dome D may only be used in the filter version F The models without suction motor operate only in the suction version and must be connected...

Page 5: ...ndicates the saturation of the filter ThisLED warnsyouwhen themetalgreasefilter needstobecleaned This LED flashes to warn you that the metal greasefiltersmustbecleaned Generally these must becleanedafter40hours of use Once thegrease filters have been cleaned press button 1 for some seconds until you hear the acoustic signal beep the LED 4 will now stop flashing When washedinadishwasher thegreasefi...

Page 6: ...ng the applianceandchangingandcleaningthefilters may cause fires Therefore we recommend observing these instructions Replacing the lamp a Disconnectthehoodfromtheelectricity b Unscrew the light shield Fig 3 c Replacethedamagedlampwithanewhalogen lampof20Wattmax d Refitthethemetalgreasefiltersandthelight shield e Beforecallingforrepairservicebecausethe hoodfailstolightup makesurethebulbsare screwed...

Page 7: ...efect is caused by misuse wear and tear dirt fire accidental damage or faulty electrical connection d If the product has been repaired or serviced by an unauthorized person e If installed contrary to Fiori Holdings Pty Ltd instructions 3 For warranty service outside of Capital City metropolitan area or outside the normal service area of the nearest authorized service provider the purchaser shall b...

Page 8: ...8 LI19UB Ed 03 07 ...