Fault: The vacuum pump doesn't start.
Has the thermo-switch switched off?
Check what has caused the switch to actuate.
Is the room temperature too low?
Raise the room temperature to a value within the prescribed range (0° - 40°).
Motor winding defective?
Please contact our Technical Team.
Unapproved substances sucked in?
Please contact our Technical Team.
Fault: Extraneous noise from the vacuum pump
Vanes are damaged?
Please contact our Technical Team.
Motor bearing damaged?
Please contact our Technical Team.
Exhaust outlet blocked?
Check the exhaust outlet connection.
Protective cover of the motor impeller damaged?
Please contact our Technical Team.
Fault: Insufficient vacuum is generated
Check the complete vacuum traverse for leaks.
Check the filter for clogging and damage.
Check the vacuum cupsfor damage/leaks.
Fault: The vacuum pump gets too hot
Check the protective cover of the motor impeller.
Please clean.
Inadequate room ventilation?
Provide adequate ventilation!
Motor supply insufficient?
Check the electrical connection!