TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
PROBLEM
1. Bugs found in wood.
2. Draft Blower will not run.
NOTE: Please verify switch is
in the "ON" position.
3. Draft blower runs continu-
ously.
4. Circulation blower will not
turn on.
SUGGESTED REMEDY
Inspect the wood for obvious signs
of insect infestation such as burrows
or holes and avoid using if possible.
Do not store indoors.
Replace toggle switch.
This can be checked by turning the
thermostat to a temperature setting
that is higher than the temperature
in your home. If the draft blower
does not operate, the thermostat may
be defective. Replace if necessary.
Replace fan relay switch.
Replace draft motor.
Review wiring diagram. If wired
correctly, seek professional
assistance.
Check by turning indicator to a lower
setting than the temperature in your
home. If the draft blower continues
to run, the thermostat may be defec-
tive. Replace if
necessary.
Check for defective wiring.
Replace fan relay center.
Have a professional heating contrac-
tor determine the proper size unit
and insulation factor of your home.
Check by moving "ON" position in-
dicator to temperature position
where the blower should turn on. If
the blower fails to run, replace the
fan limit.
PROBABLE CAUSE
• Wood has rotted or has been laying
around for an extended period of time.
• Defective toggle switch on draft
blower.
• Defective wall thermostat.
• Defective fan relay.
• Defective draft motor.
• Improper wiring.
• Defective wall thermostat.
• Thermostat wire is short cir-
cuited.
• Defective fan in relay center.
• Home is not being supplied with a
sufficient amount of heat to satisfy
the wall thermostat.
• Defective fan limit control.