background image

       23

Warranty 

Information 

          

CERTIFICATE OF LIMITED WARRANTY:

EXTENT OF COVERAGE: This warranty covers any Fire Chief Furnace sold in the United States and Canada.  This warranty applies 

only if the Fire Chief Furnace is installed, maintained, and operated in accordance with the instructions in the owner’s manual and local 

codes.  This warranty applies to the original purchaser/owner of the Fire Chief Furnace and is not transferable.  Replacement or repair 

parts are warrantied for the remaining period of the original warranty.
 

All warranty claims must include: 

 

 

•  Date of purchase

 

 

•  Model and serial number

 

 

•  Proof of purchase (dated invoice, bill of sale, cancelled check, or payment record)

 

 

•  The name / address of the store from which you purchased the furnace

Fire Chief Industries warranties the firebox and cast iron grates to be free of defects in material and workmanship for 5 years from the 

date of the original purchase. The firebox and cast iron grate warranty will be prorated after 1 year at a 20% rate each year thereafter.  

The cast iron grates are warrantied for 5 years so long as the furnace is operated safely in accordance with the owner’s manual. 

Intentional misuse or abuse causing burn through of cast iron components is NOT warrantied.  Over firing the furnace will cause the 

front face to crack and is not covered by the warranty.  Furthermore, some cosmetic deterioration can be expected as the result of 

normal operation, therefore the physical appearance is not guaranteed to remain unchanged.  The manufacturer warranties all electrical 

components for 1 year and the blower motor for 2 years.  Please be advised that the firebrick and door gaskets are excluded from this 

warranty.
In order to exercise the aforementioned warranty, a certified professional must determine the appliance/part to be defective.  He or 

she must submit a written statement to Fire Chief Industries detailing an assessment of the problem.  This assessment MUST be 

accompanied by substantiating proof of purchase (dated invoice, bill of sale, cancelled check, or payment record), model and serial 

number.  Fire Chief Industries will then authorize repair or replacement as appropriate to the submitted claim.  Fire Chief Industries will 

not honor expenses incurred from any action that was not expressly consented to in writing.  The owner is hereby notified that he or she 

will be obligated to assume liability for removal, reinstallation, shipping, and labor costs involved in servicing/repairing or replacing the 

part or unit.  The merchandise in question must be shipped via PREPAID FREIGHT to Fire Chief Industries.  Fire Chief Industries will 

return the repaired or replacement part to the purchaser on a FREIGHT COLLECT basis.
This warranty will be rendered null and void if this part/unit exhibits symptoms of obvious over-firing, deliberate abuse or negligence, 

improper installation, or is used for commercial purposes.
Finally, Fire Chief Industries will not be responsible for any claim not stated in our warranty nor does any implied warranty extend beyond 

the limits stated above.
Please contact Fire Chief Industries with all pertinent information including daytime phone number and detailed description of the type of 

problem you are having.  Fire Chief Industries technical service personnel will contact you as soon as possible.  Call 1-800-875-4788 or 

mail information to: Fire Chief Industries, 10950 Linpage Place, Saint Louis, MO  63132.

Summary of Contents for FC450

Page 1: ...URNING INDOOR FURNACE MODEL FC450 Manufactured by Fire Chief Industries 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA Revision V MAY 2015 Tested to UL391 and CSA B366 1 2011 Standards Contains Proper Burn Practices ...

Page 2: ......

Page 3: ...sture content will create creosote in the chimney and cause flue fires See Pages 10 and 13 for proper wood handling practices There should be no alteration of the Fire Chief Furnace in any way as this will void the UL391 listing and affect the operation of the furnace This will also void the warranty of the unit Fire Chief Furnace makes two types of units indoor as well as outdoor furnaces The ind...

Page 4: ...uld be noted on the freight bill at the time of delivery If upon unpacking your Fire Chief Furnace you find damage has occurred during transit notify your supplier immediately Your supplier will advise you what actions must be taken to address the problem Disclaimer Notice The listed BTU rating for your new Fire Chief Furnace was obtained using laboratory calculations The actual BTU output you exp...

Page 5: ... Ashes 13 CREOSOTE FORMATION 13 CREOSOTE PREVENTION 13 Chimney Fire Warning 13 Power Failure 13 Canadien Requirements 14 Furnace Diagram with Parts List 15 Grate System Diagram FC450 16 Blower Motor Assembly Diagram 16 Wiring Diagram 17 Troubleshooting 18 Warranty Information 23 DOUBLE CHECK TO MAKE SURE YOU HAVE RECEIVED ALL OF THE REQUIRED COMPONENTS IF YOU FIND THAT THERE IS A PART MISSING CALL...

Page 6: ...be connected to return air for the central furnace A qualified installer should perform the installation IMPORTANT FOR TECHNICAL SUPPORT OR CUSTOMER SERVICE ISSUES DO NOT RETURN TO THE DEALER THE DEALER DOES NOT HAVE REPLACEMENT PARTS CALL 1 800 875 4788 Forced Hot Air Circulation The plenum size of your Fire Chief Furnace must not be reduced to less than 10 inches in diameter or 79 square inches ...

Page 7: ...SSING CALL 1 800 875 4788 FOR FASTEST SERVICE PLEASE DO NOT GO BACK TO THE DEALER DEALER DOES NOT CARRY REPLACEMENT PARTS NOTE For your convenience your Fire Chief Furnace has been factory assembled and the electrical control assembly pre wired 1 Fasten the right and left side angle brackets to the circulation blower using 4 20 bolts and nuts Place brackets to lowest position on housing 2 Line up ...

Page 8: ... the bottom of the furnace covering the rear distribution blower Make sure the filter box is tightly pressed to the back of the furnace Use 8 10 self tapping screws included to firmly attach the filter box to the sides of the furnace Top Panel A Side Panel With Electric B Side Panel C Bottom Panel D 10 Sheet Metal Screw Twelve Places Side Panel C Bottom Panel D Side Panel with Electric B 10 Sheet ...

Page 9: ... screws provided Assemble junction box B to side of furnace usin 2 10 screws provided Mount green wire with eyelet to the bottom of the junction box mounting screw Install wires to Thermo disc posts Wires are interchangeable Re install junction box cover 6 Plug motor into the back of the electrical box 7 Plug the 3 pronged grounded plug into a grounded electrical outlet B C A ...

Page 10: ...equired to connect the furnace to the chimney should be a minimum of 24 gauge black or stainless steel NEVER USE GALVANIZED PIPE Horizontal run should not exceed 5 feet and should have a minimum rise of 2 inches per foot No installation should have more than 2 elbows a 45 elbow is recommended over a 90 elbow As a safety precaution all pipe selections should be fastened together with a minimum of 3...

Page 11: ...ing a brick chimney you must line the entire chimney with stainless steel liner The liner must be a 6 inch liner The diameter of the chimney stack should be consistent throughout the length of the chimney The chimney stack should have a built in airtight clean out WARNING Do not operate with clean out uncapped USE LISTED UL 103 TYPE HT 2100 CHIMNEY ONLY The chimney size should be at least as large...

Page 12: ...xceed 02 water column inches while developing air velocities of 450 600 feet per minute at the registers The heat outlet area should never be less than 10 inches round or 79 square inches The furnace can be installed with a cold air return system or the return air can be drawn from the basement If the return air is drawn from the basement you will have to install 3 open and close air register vent...

Page 13: ...URFACES KEEP CHILDREN AWAY DO NOT TOUCH DURING OPERATION CAUTION INSPECT FLUE PIPES JOINTS AND SEALS REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT DRAWING INTO AND ARE NOT BEING CIRCULATED BY THE AIR CIRCULATION SYSTEM CLEANING OF THE HEAT EXCHANGER FLUE PIPE AND CHIMNEY IS ESPECIALLY IMPORTANT AT THE END OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE SUMMER MONTHS CAUSED BY THE AC...

Page 14: ...wing you to add more wood do not overload which would smother the fire Add more wood slowly so the flames have time to engulf the fresh wood Once the fire is burning and there is a glowing ember bed adjust the draft to achieve desired burn pattern Learning how to adjust the draft to maintain the desired temperature for your home may take several days After a short time you will know which settings...

Page 15: ...tuminous coal start the fire with wood as described above Always use dry kindling as this will provide a hotter fire and add small pieces of wood until you get a good hot ember bed At this point add a small amount of coal When the coal is hot enough to ignite add small amounts at a time so as not to smother the fire Keep in mind that Bituminous coal will require more maintenance as this type of co...

Page 16: ...EALER THE DEALER DOES NOT HAVE REPLACEMENT PARTS CALL 1 800 875 4788 Creosote Formation and Need for Removal When wood is burned slowly it produces compounds in exhaust smoke which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cooled chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this cre...

Page 17: ...N WITH APPROPRIATE DUCTWORK CONFIGURATIONS ONLY DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL GAS OIL ELECTRIC FURNACE INSTALLATION DO NOT CONNECT TO ANY GAS FURNACE THAT HAS NOT BEEN CERTIFIED INITIALLY AS COMPLYING WITH CAN CGA 2 3 THE OPERATION OF THE GAS FURNACE MUST BE VERIFIED FOR ACCEPTABLE OPERATION BEFORE AND AFTER INSTALLATION OF THE ADD ON APPLIANCE BY A GAS FITTE...

Page 18: ...1 Draft Control FCDCA 3 1 Furnace Shell FC45SHELL 4 1 Right Side Panel with Insulation FC45RA 5 1 Thermo Disc FCTDADJ 6 1 Electrical Box FC45ECC 7 1 Filter Box FCFB 8 1 Blower Assembly FC3SPMOTOR 9 1 Top Panel FC45TOP 10 1 Left Side Panel with Insulation FC45LA 11 4 Door Hinge Pin FCDP 12 1 Fuel Door Assembly FCFDA 13 1 Spin Draft FCSD ...

Page 19: ...am 1 2 FC450 PARTS LIST 1 10 FIRE BRICK 2 2 WOOD GRATES PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR 1 3 BLOWER MOTOR 1 4 2 1 3 4 FC450 PARTS LIST 1 1 BLOWER WHEEL 2 1 BLOWER HOUSING 3 1 MOTOR CAPACITOR 4 1 BLOWER MOTOR ...

Page 20: ...o adjust settings Note Never attempt to make adjustments while a fire is burning in the furnace 1 Make sure power cord is disconnected from electric outlet Caution to prevent electrical shock never attempt to adjust Thermo Disc with electric connected 2 Remove cover from 2 X 4 electric junction box on side of furnace 3 Adjust the dial on the Thermo Disc clockwise for the blower to turn on and off ...

Page 21: ...e securely to the shaft Possible Causes Remedies Balance weights on squirrel cage have become dislocated You may attempt to adjust the weights yourself to obtain an acceptable balance If you are unsuccessful contact your supplier Return the blower to your supplier for replacement Defective main bearings 2 3 18 Problem Circulation blower will not turn on Defective fan Thermo Disc switch If the blow...

Page 22: ... 5 feet and has a 2 inch rise per foot The run should not contain more than 2 elbows Replace with a larger flue providing a minimum of 50 square inches but not more than 100 square inches of draft area If the flue is within these specifications check the draft with a draft gage manometer Your flue should provide a minimum of 04 water column inches and a maximum of 08 water column inches Too many e...

Page 23: ...ly sufficient amount of oxygen for combustion Install an aperture to the outside consisting of a minimum of 12 square inches or 4 inches round Install stainless steel liner in masonry chimney to reduce creosote formation and improve draw Use appropriate size stainless liner for the furnace DANGER Never use uninsulated stove pipe as chimney It must not be used on the inside of your home due to high...

Page 24: ... obstruction outside chimney such as a tree Flue is located too close to the peak of the roof or does not rise above it to provide the proper draft Backdraft damper is in the closed position 9 Problem Odor detected in home during initial firing There is an oily film that remains on the steel after the manu facturing process Firing the furance has raised the tempera ture of the fire box to a level ...

Page 25: ...d cooling contractor Check and replace filter Proper filter size is 20 by 25 by 1 Furnace room may be too airtight Install an aperature to the outside consisting of a minimum of 12 square inches or 4 inches round Consult a professional to determine correct sizing Excessive dirt accumulation in air filter Combustion chamber not receiving an adequate amount of oxygen Furnace size is inadequate for y...

Page 26: ...be advised that the firebrick and door gaskets are excluded from this warranty In order to exercise the aforementioned warranty a certified professional must determine the appliance part to be defective He or she must submit a written statement to Fire Chief Industries detailing an assessment of the problem This assessment MUST be accompanied by substantiating proof of purchase dated invoice bill ...

Page 27: ......

Reviews: