background image

Mini T

6

6

Outdoor Range

© Copyright 2004 - 2009 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. 

www.ecosmartfire.com

Conditions of Use

1. For the purposes of this model specification 
we refer to the fuel used in the EcoSmart™ Fire 
as 

Denatured Ethanol*.  

*There are many different names for this 
fuel around the world. Please refer to www.
ecosmartfire.com for a list of commercially 
available fuel names in your country.

Denatured Ethanol* is classified as a 
Dangerous Goods Flammable Liquid 
Class 3, PGII and is regulated by specific 
standards and rules. You must familiarise 
yourself with the appropriate regulations of 

your country in order to safely and legally 
store, handle, decant and use this fuel. 

The customer warrants to The Fire Company 
Pty Ltd that after delivery of their EcoSmart™ 
Fire and whilst The Fire Company Pty Ltd 
retains any interest in the goods or consigned 
goods (as the case may be) the customer shall 
comply with all applicable Acts, Regulations 
and Laws dealing with the transport, unloading 
and storage of Dangerous Goods.

2. Children do not recognize the dangers that 
can arise when handling Dangerous Goods, 

nor do they recognize the volatility of flammable 
liquids when ignited. Please ensure you keep 
children at a safe distance and supervised at all 
times when operating the fire.

3. Approval from building authorities may 
be required. Please ensure you contact the 
appropriate parties before installing your 
EcoSmart™ Fire.

4. It is a condition of purchase that you obtain 
a fire extinguisher Ammonium Phosphate 
AB:E type. These can be purchased from your 
distributor or independently.

Warnings

1. Risk of explosion:  
a) never use any fuel other than the fuels 
specifically identified for use in the appliance. 
never use gasoline. 
b) never fill the fuel reservoir when it is operating 
or still hot.  
c) never fill fuel reservoir in areas where 
flammable vapours or gas may be present.  
d) never store or transport the fuel in other than 
a metal or plastic container that is:  
1. Acceptable for use with the specific fuel.  
2. Is in the original container for the alcohol fuel.

2. never store fuel in the living space where  
the fire is situated.

3. Due to high surface temperatures, keep 
children, pets, clothing, and furniture away. 

The unit is hot while in operation, contact with 
the EcoSmart™ Fire may cause skin burns.

4. Risk of indoor air pollution – use EcoSmart™ 
Fires only in well-ventilated areas. People with 
breathing problems should consult a physician 
before using the appliance.

5. Do not use the EcoSmart™ Fire to heat 

or boil water or as a cooking appliance. Do 
not throw waste materials or paper into the 
EcoSmart™ Fire.

6. EcoSmart™ Fires have not been tested with 
an unvented gas log set. To reduce the risk of 
fire or injury, do not install an unvented gas log 
set into this appliance.

7. The EcoSmart™ Fire has not been tested 
for use with doors. To reduce the risk of fire or 
injury, do not install doors.

8. It is recommended that the EcoSmart™ Fire 
be fixed into position to avoid displacement as 
per instruction provided with each model.

9. Do not dismantle the EcoSmart™ Burner.

10. Do not attach any other tank to the 
EcoSmart™ Burner.

11. EcoSmart™ Fires must only be operated 
using authorised accessories & equipment.

12. Do not obstruct the open/close sliding 
mechanism of the EcoSmart™ Burner in any 
way as this could result in the jamming/non 
functionality of the shut off mechanism.

13. The EcoSmart™ Burner should not be started 
if a fault is suspected or when there appears to be 
any damage to the burner or its housing.

14. The use of any fitting other than those 
available from or recommended by The Fire 
Company Pty Ltd for the EcoSmart™ Firebox 
and Burner is not permitted.

15. The Fire Company Pty Ltd does not accept 
responsibility for any damage which occurs if the 
EcoSmart™ Fire is used for purposes other than 
those for which it is intended, or if it is incorrectly 
operated or repaired by unqualified persons. 

16. The EcoSmart™ Fire is not intended to 
operate continuously. To avoid heat expansion 
and potential splitting of the timber framework in 
Designer Range models please ensure that the 
model is allowed to cool down completely on a 
regular basis. 

If you have any questions regarding any of the 
above important safety information please contact 
your distributor or The Fire Company Pty Ltd.

Testing & Compliance

The EcoSmart™ Fire is manufactured 
by The Fire Company Pty Ltd whose 
quality management system is 
certified as being in conformity with 
ISO 9001:2000.

   

 

The EcoSmart™ Fire Collection has achieved  
Swedish Institute for Technical Approval in 
Construction (SITAC) approval.

The EcoSmart™ Fire is 
the first product of its kind 
to have its collection so 
comprehensively C-UL US 
listed. For the most up to 

date list of C-UL US Listed models and 
compliance requirements please contact your 
local distributor.

Instructions and specifications for the EcoSmart™ 
Fire were tested as far as practicable to a selection 
of clauses from AS4553/AG103 – Australian 
Standard for Gas Space Heaters (closest 
comparable product at the time of invention)

Investigation into applicable standards and 
testing platforms for compliance to GS & CE 
were held and The Fire Company has gained 
a Compliance Verification Declaration from 
Globalnorm GmbH.

EcoSmart Fire is TÜV certified in Germany 
when using Burner Two within a Firebox 
setting. For further information, please contact 
your distributor.

Some models from the EcoSmart™ Fire Collection have achieved the following certification and approvals:

Reviews: