Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris. Use this
appliance in a well-ventilated space only. Do not use it in a building, garage, or any other enclosed
area.
Use this appliance in outdoor areas described below:
(a)
With walls on all sides, but at least one permanent opening at ground level and no overhead
cover.
(b)
Within a partial enclosure that includes overhead cover and no more than two walls. These
walls may be parallel, or at right angles to each other.
(c)
Within a partial enclosure that includes overhead cover and no more than two walls. The
following shall apply:
(i)
One wall that is equivalent to at least 25% of the total wall area is completely open.
(ii)
30% or more in total of the remaining wall area is open and unrestricted.
This fire table is designed for use with a 20 lb. liquid propane gas
(LP) tank. The LP-gas supply cylinder to be used must be:
(a)
Constructed and marked in accordance with the
Specifications for LP-gas cylinders of the U.S. Department of
Transportation of Dangerous Goods and Commission,
CAN/CSA-B339, as applicable;
(b)
Provided with a listed overfilling prevention device; and
(c)
Provided with a cylinder connection device compatible with
the connection for the appliance.
If the propane gas tank is leaking gas, you may hear, see, or smell
a hiss. Do the following:
(a)
Disconnect the propane gas tank.
(b)
Do not attempt to fix the problem yourself.
(c)
Contact your gas supplier or fire department for help.
A leak test should always be performed after attaching the connection to the LP gas cylinder
service valve.
Disconnect the cylinder when the appliance is not in use.
Check for leaks after not using the unit for long period of time.
Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed
from the appliance.
Store the cylinder outdoors in a well-ventilated area (not in a building, garage, or other enclosed
area) out of the reach of children.
The cylinder used must include a collar to protect the cylinder valve.
Do not store a spare or disconnected liquid propane cylinder under or near this unit..
Never fill the cylinder beyond 80 percent full;
Place the dust cap tightly on the cylinder valve outlet whenever the cylinder is not in use. Install
only the type of dust cap on the cylinder valve that is provided with the cylinder valve. Other
types of caps or plugs may result in a propane leak.
Inspect the visible portion of the hose before each use of the appliance.