- 15 -
NOTE:
1) The cylinder must be provided with a shut off valve terminating in
a LPG supply cylinder valve outlet specified, as applicable, for
connection NO 510 in the standard for compressed gas cylinder
valve outlet and inlet connections, ANSI/CGA-v-1.
2) The cylinder supply system must be arranged for vapor
withdrawal.
3) The cylinder used must include a collar to protect the cylinder
valve.
Annually check operation:
A. Open the front panel of the base assembly.
B. Open the propane tank valve.
C. Spoon several drops (or use squirt bottle) of the solution onto gas
hose connection and pilot connection.
D. Inspect the connections and look for bubbles.
E. If no bubbles appear, the connection is safe.
F. If bubbles appear, there is a leak. Close the propane tank valve and
loosen and re-tighten this connection.
G. Check for leaks again.
H. If bubbles still appear, close the propane tank and refer to
instructions under #8 on page 14. DO NOT attempt to use the
heater.
ASSEMBLY