9
WALL
WALL MOUNTING WITH BRACKET
Allow the Heat Sensor to reach room temperature before use.
See the table and follow the instructions from 1-4.
Starting the Sensor
Remove the red battery discon-
nection piece (B) and return
Heat Sensor on the mounting
plate.
Press the Heat Sensor cover
(LED (A) flashes green).
Keep the battery disconnection
piece for future use.
Set sensitivity level
Set the Heat Sensor’s sensitivity level according to the table below.
See page 18.
MOUNTING HEIGHT
SENSITIVITY LEVEL CONFIGURATION
Sensitivity
Acknowledgement “beep(s)”
80 cm (recommended)
3 presses
70-79 cm
*
3 presses
65-69 cm
*
4 presses
3
B
A
Watch the film on sensitivity
configuration (48 sec.)
goog.gl/eS3oZF
3
4
* For wall mounting lower than 80 cm and horizontal mounting 81-100 cm below the fan,
the sensor will not in all cases meet all EN standard requirements.