13. User Controls
POWER SUPPLY ON
FIRE
FIRE ROUTING ACTIVE
GENERAL FAULT
POWER SUPPLY FAULT
SYSTEM FAULT
EARTH FAULT
FUSE FAILED
REPEATER FAULT
SOUNDER FAULT/DISABLED
SOUNDER TEST
FIRE PROTECTION FAULT/DISABLED
FIRE ROUTING FAULT/DISABLED
FAULT ROUTING FAULT/DISABLED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
O I
FIRE
1. THE RED ZONE INDICATOR
WILL PULSE SHOWING THE
LOCATION OF THE FIRE.
2. CARRY OUT THE
REQUIRED FIRE DRILL.
3. TO SILENCE ALARMS
PRESS SILENCE ALARMS.
4. TO RESET FROM THE FIRE
CONDITION PRESS RESET.
FAULT
1. DETERMINE THE CAUSE
OF THE FAULT.
2. PRESS SILENCE BUZZER.
3. CALL YOUR SERVICE
ENGINEER.
SYSTEM FAULT
THE PANEL IS INOPERATIVE.
ARRANGE FOR
ALTERNATIVE FIRE
DETECTIN MEASURES.
EVACUATE
SILENCE/
RESOUND
ALARMS
RESET
SILENCE
BUZZER
DELAY
ON/OFF/
OVERRRIDE
SELECT
ON/OFF
TEST DISPLAY
ENABLE
DISABLE
TEST
SELECT
DISABLEMENT AND TEST
1. PRESS SELECT ON/OFF.
THE LED WILL ILLUMINATE.
2. SELECT THE ZONE OR
OUTPUT USING
↑ AND ↓
. THE
FAULT LED WILL PULSE.
3. PRESS DISABLE OR TEST.
4. TO RE-ENABLE, SELECT
THE ZONE OR OUTPUT AND
PRESS ENABLE.
04:45:34
D/N ON
Switch
Functionality
Button Availability
Evacuate
Operates all sounders continuously and lights the RED LED next to
the button until the Silence/Resound Alarms button is operated
When controls are unlocked
Silence/Resound
Alarms
When the sounders are operated, 1st press stops sounders. If a zone
is in fire, the General Fire LED and the Zonal fire LED will change
from flashing to steady. 2nd press restarts the silenced sounders if a
zone is in fire.
When controls are unlocked
Reset
Clears the panel display, resets the zones, outputs and operates the
reset relay.
When controls are unlocked and [if
silence before reset is configured]
sounders are silenced.
Silence Buzzer
1] Press to stop the buzzer sounding in fire or fault conditions.
Always available.
2] In 2-Stage Delay Mode, with stage 1 delay running, press to start
stage 2 delay, otherwise all delayed outputs operate when Stage 1
timer times out.
When the panel is in the fire
condition and the delay is running.
Delay
On/Off/Override
1] Press once to Enable the delay mode, lighting the adjacent delay
on LED. Press again to disable the delay mode and turn off the LED
1] When controls are unlocked
and delay period is not zero.
2] Overrides the delay when delay is running. All delayed outputs will
operate immediately.
2] When the delay is running.
Select On/Off
Enables the USER SELECT feature [Select ↑, Select ↓] for selection of
zones or outputs for disablement/re-enablement & Day/Night On/Off
selection and setting current time on Clock Module if fitted.
When controls are unlocked
Test Display
Press to illuminate all LEDs on the display and operate the buzzer. All
indications remain active for approx 5 seconds. Also displays alarm
count on Clock Module if fitted.
Always available
Enable
Press to clear the disablement or test condition on a zone or output
selected via the User Select feature.
When controls are unlocked, the
Select switch has been operated
and a zone or output has been
selected.
Disable
Press to disable a zone or output selected via the User Select feature. As above.
Test
Press to initiate the One Man Test on sounders or zones as selected
via the User Select feature.
As above.
Select ↑ Select ↓
Used to scroll the cursor indication through the zone and output fault
LEDs on the display to select a zone or output for disablement,
enablement or test. [LED illuminated when Select Mode is active].
Also scrolls through Clock Module menu when fitted.
When controls are unlocked and
the Select switch has been
operated.
Access Controls Keyswitch:
O – Controls Locked
I – Controls Unlocked