Page 24
Pyxis User Manual V3.2 with accessories
Pyxis Battery Extender Module Technical Information
Model
Pyx/BEM/750
Battery Storage Type
AGM
Battery Bank Voltage (V)
12
Battery Bank Capacity (Ah)
110 (C20)
DC Input/Output Connection
2 x 120 A 12 V DC Grey SB120 Anderson
Setup Time
1 Minute
Water/Ingress Protection
IP44
Operating Temperature Range
-10°c - 45°c
Dimensions (W x D x H)
560 mm x 350 mm x 340 mm
Packaged Dimensions (W x D x H)
720 mm x 495 mm x 485 mm
Weight (kg)
40.5
Packaged Weight (kg)
44.89
Recommended no of persons for lifting
2
Warranty
2 Years
5.2 Warnings
5.2.1
Safety notice
regarding The units’
Batteries
Servicing of the batteries should be
performed or supervised by
personnel knowledgeable about
batteries and required precautions.
When replacing batteries, replace
with the same type and number of
batteries.
CAUTION: Do not dispose of
batteries in a fire. The batteries
may explode.
CAUTION: Do not open or
mutilate batteries. Released
electrolyte is harmful to the skin
and eyes. It may be toxic.
Pyxis run Times* (no External charge)
Model
Pyx/400/250
Pyx/400/250
+ Battery
Extender
Pyx/400/250
+ 2 x Battery
Extenders
Pyx/800/250
Pyx/800/250
+ Battery
Extender
Pyx/800/250
+ 2 x Battery
Extenders
run Time at 100 W Output e.g. Plasterer’s Light, Laptop, 55” Smart TV
2:40
10:00
17:30
2:40
10:00
17:30
run Time at 200 W Output e.g. 18 V cordless drill Fast charger, desktop Pc & Monitor
1:15
5:00
8:40
1:15
5:00
8:40
run Time at 300 W Output e.g. Oscillating Multi-Tool, Kitchen Food Blender
0:30
2:50
5:10
0:30
2:50
5:10
run Time at 500 W Output e.g. SdS hammer drill, Wall Mounted heater
-
-
-
0:20
1:40
3:00
* (Hours:Minutes), all run times are approximate
5.1 Pyxis Run Times
E & OE,
©2014 Firefly Solar Generators Ltd.
info@fireflysolar.net
www.fireflysolar.net
+44 (0)1273 40 95 95
Scan to view the Pyxis video online. Alternatively, use this link:
www.fireflysolar.net/pyxis-video