background image

REV. B          Page 4

Burning Spur Kit

SPECIFICATIONS

Table 1

  Installation specifications

Fig. 1

  Burning Spur Dimensions; refer to Table 1.       

Models:

Orifice NG Btu’s

Orifice LP

DBS-12/ DBS-12K

OAS-NG34

50,000 

(14.65kW)

OAS-LP47

DBS-16/ DBS-16K

OAS-NG29

75,000 

(21.98kW)

OAS-LP41

DBS-22/ DBS-22K

OAS-NG22

100,000 

(29.31kW)

OAS-LP35

DBS-31/ DBS-31K

OAS-NG05

175,000 

(51.29kW)

OAS-LP26

DBS-36/ DBS-36K

OAS-NG01

225,000

(65.94kW)

OAS-LP19

Table 2 

 Btu Specifications

Burner ModelS

Spur Burner Only/ Spur Burner Kit

Pan/Disc 

Depth

A  

Outer       

Diameter

Min. Inside 

Opening           

Dimension

B

Combustible

Side Wall

C

Combustible

Ceiling

D

Combustible

Floor

DBS-12/ DBS-12K

2 ½” - 3”

12”

15”

36”

96”

18”

DBS-16/ DBS-16K

2 ½” - 3”

16”

19”

36”

96”

18”

DBS22/ DBS-22K

2 ½” - 3”

22”

25”

36”

96”

18”

DBS-31/ DBS-31K

2 ½” - 3”

31”

34”

36”

120”

18”

DBS-36/ DBS-36K

2 ½” - 3”

36”

39”

36”

120”

18”

Disclaimer:

 Btu listings are based on 7.0”WC for Natural Gas 

and 11.0”WC for Liquid Propane (LP) at the burner orifice.  Flex 

line size and proper gas pipe sizing will also affect Btu’s.  As a 

result your Btu’s may vary slightly from Table 2 specifications.

Fig. 2

  Clearance to Combustibles 

(Not to be used in an enclosed space)

BEFORE INSTALLING A BURNING SPUR DETERMINE WHAT PAN WILL BE USED:

The Spur Burner models above are not provided with pans for installation.  We suggest you provide an appropriate non-

combustible burner pan to install the Burning Spur.  Burner pans sizes listed in Table 1 are suggested sizes based on the 

burning spur model size.  The pans can be round, square or a flat metal. 

NOTE

:  It is recommended to use 304 

Stainless Steel. Burner pans should have ¼” drainage holes to prevent standing water in pan and the center hole for the 

burner nipple should be ⅞” in diameter.  A recommended material thickness for any burner pan or disc is 16 gauge. Once 

the Burning Spur is installed into a burner pan then proceed with this manual to complete the installation.

CAUTION: DO NOT use stiff screen or perforated metal as a burner pan. Some gases are heavier than air and 

screen or perforated metal can enable the gas to flow down inside an enclosure which could cause delayed 

ignitions or explosions.

A

C

B

D

CL

24”

     Max 

Overhang

(Center Line)

Description:

 Spur Burners are provided with a burner and Natural gas (NG) orifice only (i.e. DBS-12) and Spur Burner 

Kits are provided with Spur Burner, Natural gas (NG) orifice, key valve assembly and flex line (i.e. DBS-12K).

Note:

  An LP conversion kit must be ordered seperate.

Pressure

NG

LP

Min. Inlet

5.0” WC

 

(1.24 kPa)

10.5” WC

 

(2.61kPa)

Max. Inlet

10.5” WC (2.61kPa)

13.0” WC (3.23kPa)

Normal Inlet

7.0” WC (1.74kPa)

11.0” WC (2.73kPa)

Table 3

  Gas Pressures

Summary of Contents for DBS-12

Page 1: ...inch Spur Burner Kit 50 000 Btu s DBS 16 16 inch Spur Burner DBS 16K 16 inch Spur Burner Kit 75 000 Btu s DBS 22 22 inch Spur Burner DBS 22K 22 inch Spur Burner Kit 100 000 Btu s DBS 31 31 inch Spur...

Page 2: ...ave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause i...

Page 3: ...as the potential to crack or pop outside the fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rain...

Page 4: ...Burner models above are not provided with pans for installation We suggest you provide an appropriate non combustible burner pan to install the Burning Spur Burner pans sizes listed in Table 1 are su...

Page 5: ...all Liquid Propane LP tanks outside the enclosure 6 To prevent performance problems with LP gas fire pits do not use a LP tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas sh...

Page 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Page 7: ...to keep the enclosure dry 9 These products are designed for outdoor use only Not approved for any indoor use or any enclosed space 10 This fire pit is designed to have Firegear Outdoors lava rock or g...

Page 8: ...mended to use the key valve assembly provided in the Burning Spur kit Otherwise you will need to provide a key valve for the installation GAS FLOW Burner Pan OAS U3 8D S BURNING SPUR ASSEMBLY Fig 5 Na...

Page 9: ...hut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the ma...

Page 10: ...use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or Propane gas line WARNING 1 This appliance is hot when...

Page 11: ...REV B Page 11 Burning Spur Kit REPLACEMENT PARTS 1 2 5 4 Drawings not to scale 8 9 3 O N O F F 6 7...

Page 12: ...ecific orifice sizes model numbers 3 OAS Orifice air shutter for LP Gas Fire Pits 1 Refer to page 4 of manual for specific orifice sizes model numbers 4 1 2 Flex Gas Line 46 inch Length used with all...

Page 13: ...B Spur OAS U3 8D S Burning Spur Only Contents Models DBS 12 DBS 16 DBS 22 DBS 31 DBS 36 GAS FLOW 12 inch Key T200 9898 46 Key Valve U1 8D S B Spur Flange OAS U3 8D S Burning Spur Kit Contents Models...

Page 14: ...OAS LP26 DBS 31 DBS 31K OAS LPK19 S499 8 113 SS4 D5 U3 8D S 225 000 65 94kW OAS LP19 DBS 36 DBS 36K When converting Burners to LP gas the main burner orifice must be kept a minimum of 6 inches away fr...

Page 15: ...the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usually a golden or brown hue This disc...

Page 16: ...lass Reflective Glass Sold in 5lb bags in various colors See your Firegear dealer for various options Paver System Model PAVER CP MT Paver bracket key valve parts for match throw system Model PAVER CP...

Page 17: ...NTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONST...

Page 18: ...A BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTEC...

Page 19: ...defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Fire...

Page 20: ...or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale i...

Page 21: ...REV B Page 21 Burning Spur Kit Notes...

Page 22: ...rial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of...

Reviews: