REV. B Page 4
Burning Spur Kit
SPECIFICATIONS
Table 1
Installation specifications
Fig. 1
Burning Spur Dimensions; refer to Table 1.
Models:
Orifice NG Btu’s
Orifice LP
DBS-12/ DBS-12K
OAS-NG34
50,000
(14.65kW)
OAS-LP47
DBS-16/ DBS-16K
OAS-NG29
75,000
(21.98kW)
OAS-LP41
DBS-22/ DBS-22K
OAS-NG22
100,000
(29.31kW)
OAS-LP35
DBS-31/ DBS-31K
OAS-NG05
175,000
(51.29kW)
OAS-LP26
DBS-36/ DBS-36K
OAS-NG01
225,000
(65.94kW)
OAS-LP19
Table 2
Btu Specifications
Burner ModelS
Spur Burner Only/ Spur Burner Kit
Pan/Disc
Depth
A
Outer
Diameter
Min. Inside
Opening
Dimension
B
Combustible
Side Wall
C
Combustible
Ceiling
D
Combustible
Floor
DBS-12/ DBS-12K
2 ½” - 3”
12”
15”
36”
96”
18”
DBS-16/ DBS-16K
2 ½” - 3”
16”
19”
36”
96”
18”
DBS22/ DBS-22K
2 ½” - 3”
22”
25”
36”
96”
18”
DBS-31/ DBS-31K
2 ½” - 3”
31”
34”
36”
120”
18”
DBS-36/ DBS-36K
2 ½” - 3”
36”
39”
36”
120”
18”
Disclaimer:
Btu listings are based on 7.0”WC for Natural Gas
and 11.0”WC for Liquid Propane (LP) at the burner orifice. Flex
line size and proper gas pipe sizing will also affect Btu’s. As a
result your Btu’s may vary slightly from Table 2 specifications.
Fig. 2
Clearance to Combustibles
(Not to be used in an enclosed space)
BEFORE INSTALLING A BURNING SPUR DETERMINE WHAT PAN WILL BE USED:
The Spur Burner models above are not provided with pans for installation. We suggest you provide an appropriate non-
combustible burner pan to install the Burning Spur. Burner pans sizes listed in Table 1 are suggested sizes based on the
burning spur model size. The pans can be round, square or a flat metal.
NOTE
: It is recommended to use 304
Stainless Steel. Burner pans should have ¼” drainage holes to prevent standing water in pan and the center hole for the
burner nipple should be ⅞” in diameter. A recommended material thickness for any burner pan or disc is 16 gauge. Once
the Burning Spur is installed into a burner pan then proceed with this manual to complete the installation.
CAUTION: DO NOT use stiff screen or perforated metal as a burner pan. Some gases are heavier than air and
screen or perforated metal can enable the gas to flow down inside an enclosure which could cause delayed
ignitions or explosions.
A
C
B
D
CL
24”
Max
Overhang
(Center Line)
Description:
Spur Burners are provided with a burner and Natural gas (NG) orifice only (i.e. DBS-12) and Spur Burner
Kits are provided with Spur Burner, Natural gas (NG) orifice, key valve assembly and flex line (i.e. DBS-12K).
Note:
An LP conversion kit must be ordered seperate.
Pressure
NG
LP
Min. Inlet
5.0” WC
(1.24 kPa)
10.5” WC
(2.61kPa)
Max. Inlet
10.5” WC (2.61kPa)
13.0” WC (3.23kPa)
Normal Inlet
7.0” WC (1.74kPa)
11.0” WC (2.73kPa)
Table 3
Gas Pressures