SPECIFICATIONS
Table1. Fire Pit Dimensions
36”
96”
24”
Maximum
Overhang
Center of Flame
!
A
B
C
.875 TYP. (usable flat lip)
*
*
D
Ground Level
Figure 1. Fire Pit dimensions; refer to Table 1. (Dimensions applicable to
round or square pans)
Figure 2. Clearance to Combustibles
(Not to be used in an enclosed space)
REV. 10-24-12 Page 4
Model
Btu’s
Natural/Propane (LP)
Factory Orifice
NG LP
FPB-19MT/N
60,000 Btu’s
#31
#44
FPB-25MT/N
100,000 Btu’s
#22
#34
FPB-1212MT/N
20,000 Btu’s
#50
#55
FPB-1414MT/N
36,000 Btu’s
#42
#51
FPB-2020MT/N
60,000 Btu’s
#31
#44
FPB-2626MT/N
100,000 Btu’s
#22
#34
FPB-3232MT/N
160,000 Btu’s
#8
#28
FPB-3838MT/N
200,000 Btu’s
#2
#22
FPB-5050MT/N
240,000 Btu’s
#0
#18
NG
LP
Min.
Inlet
5.0”WC
11.0”WC
Max.
Inlet
10.5”WC 13.0”WC
Table 3. Gas Pressures
Model
A
Pan Depth
B
Min/Max
Install Opening
C
Inside Pan
D
Ground Level
FPB-19MT/N
(Rd.)
2.625”
19.25”/21.5”
19”
8”
FPB-25MT/N
(Rd.)
2.625”
25.25”/27.5”
25”
8”
FPB-1212MT/N
(Sq.)
2.625”
12.25”/13.75”
12”
8”
FPB-1414MT/N
(Sq.)
2.625”
14.25”/15.75”
14”
8”
FPB-2020MT/N
(Sq.)
2.625”
20.25”/21.75”
20”
8”
FPB-2626MT/N
(Sq.)
2.625”
26.25”/27.75”
26”
8”
FPB-3232MT/N
(Sq.)
2.625”
32.25”/33.75”
32”
8”
FPB-3838MT/N
(Sq.)
2.625”
38.25”/39.75”
38”
8”
FPB-5050MT/N
(Sq.)
2.625”
50.25”/51.75”
50”
8”
Note:
Fire pits are rated at maximum Btu’s which is dependent upon proper gas pipe sizing. Flex line size also affect
Btu’s. As a result your Btu’s will may vary from Table 2 specifications listed above.
Table 2: Btu Specifications based on 7.0”WC - NG and 10.0”WC -LP
Matchlight Fire Pits