background image

REQUIREMENTS

1.   Only non-combustible materials should come in direct contact with any part of the Fire Pit. Underneath area should  

      be non-combustible as well.
2.   Only use ¾” gas supply line to the Fire Pit. Based on the selection of the fire pit size, the proper brass fittings should   

      be used to ensure a proper installation.
3.   Determine the size of the round or square Fire Pit you are preparing to install (Refer to page 3).
4.   You must provide a round or square opening out to place the fire pit into the non-combustible enclosure surround.  

       Do not exceed the maximum opening from Table 1, dimension B.
5.   Follow the local code requirements for the gas type being used. This Fire Pit should be installed in accordance with  

      local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1   

      NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.
6.   Fire Pits create high temperatures, it is very important to have any combustibles at a safe distance. 
7.  

CAUTION: 

A minimum of 18 square inches of cross ventilation (per side) is required to keep the enclousure  

      dry.

8.  These products are designed for outdoor use only. Not approved for any indoor use. 
9.  This Fire Pit is designed to have Lava Rock/Media completely covering the fire star burner, so that the fire star is  

        invisible. Do not cover more than 1” above the top of the covered fire star burner. When purchasing Lava Rock it  

        is recommended to use minimum of 1” diameter as a base to fill the burner pan. Decorative glass covering may  

        be loosely scattered on top of the rock if desired or non-combustible logs may be added for a campfire look. If logs  

        are chosen, do not place on decorative glass base, use only Lava Rock as the base.   

NOTE

: If using all glass  

        media, glass must be a minimum of 1/4-inch diameter or larger.
10.  Gas lines and fittings must be installed in to the non-combustible structure. All gas connections must be leak tested  

       before installation of the fire pit. Soapy water leak detection is required before regular use of the fire pit.
11.  Do not use material that will absorb moisture over time and will not release this moisture quickly. Moisture can boil  

       in this material and can rapidly break apart and cause damage or personal injury.
12.  Never leave any other combustible material on top of the fire pit. This could cause unsafe operation of this system  

       and damage to the component that will not be covered under our warranty.
13.  Cover the complete burner with lava or decorative Rock material (min. 1-inch diameter). Completely cover the   

       star burner, no more than 1-inch above the firestar burner.

INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE

REV. 10-24-12  Page 6

INSTALLING KEY VALVE AND PIEZO IGNITOR

The key valve contents: 1- key valve, 1- key and 1- flange.  (See figure 4).  The valve requires a 1 1/4” round clearance 

hole in the non-combustible enclousure wall.  See the instructions supplied with the key valve for more specific details. 

Note: Be sure to leak test all fitting before operation.  Figure 5 shows an example of a typical installation. 

 

After the fire pit pan is installed run the piezo ignitor wires into the electrical junction box. Piezio wires are 24-inches in 

length; ensure your installation does not exceed the wire length for proper connection.

Primary Gas 

Supply 

ON

O

FF

Fig.  4 Key valve components.

Matchlight Fire Pits

Summary of Contents for FPB-1212MSI/N

Page 1: ...ross ventilation Failure to provide proper ventilation can void the warranty Match Throw Description Manual Spark FPB 19MT N 19 rd pan firestar FPB 19MSI N FPB 25MT N 25 rd pan firestar FPB 25MSI N FPB 1212MT N 12 x12 sq pan firestar FPB 1212MSI N FPB 1414MT N 14 x14 sq pan firestar FPB 1414MSI N FPB 2020MT N 20 x20 sq pan firestar FPB 2020MSI N FPB 2626MT N 26 x26 sq pan firestar FPB 2626MSI N FP...

Page 2: ...8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 03 1 3 4 1 ...

Page 3: ...alve Piezo Ignitor 5 Typical Installation Drawings 6 Installing Battery in Piezo Ignitor 7 Ignitor Alignment 7 Installation of Lava Rock Media 7 Operation 8 Lighting Instructions 8 Air Shutter Adjustment 8 Replacement Parts 9 Replacement Parts List 10 Fire Pit Maintenance Trouble Shooting 11 Optional Accessories Conversion Kits 11 12 Warranty 13 TABLE OF CONTENTS NOTE This installation instruction...

Page 4: ... inches 3 23 cm for each pound of propane LP contained in the tank see example below Every opening must have minmum dimensions to allow entrance of a 1 2 3 2 mm diameter rod Ventilation openings in side walls must not connunicate directly with other enclosures of the fire pit The cyclinder valve must be easily accessible by hand Connections should be easy to leak test inside the enclosure A door o...

Page 5: ... 2 22 FPB 5050MT N 240 000 Btu s 0 18 NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level FPB 19MT N Rd 2 625 19 25 21 5 19 8 FPB 25MT N Rd 2 625 25 25 27 5 25 8 FPB 1212MT N Sq 2 625 12 25 13 75 12 8 FPB 1414MT N Sq 2 625 14 25 15 75 14 8 FPB 2020MT N Sq 2 625 20 25 21 75 20 8 FPB 2626MT N Sq 2 625 ...

Page 6: ...flared brass fitting to the end of the black iron pipe Be sure to clean the pipe threads and use Teflon tape or pipe sealant 5 Connect the female flared flex connector from the Fire Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified i...

Page 7: ...esired or non combustible logs may be added for a campfire look If logs are chosen do not place on decorative glass base use only Lava Rock as the base NOTE If using all glass media glass must be a minimum of 1 4 inch diameter or larger 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections must be leak tested before installation of the fire pit Soapy w...

Page 8: ...ble Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Non Combustible Wall Material Non Combustible Wall Material Securing Tab Securing Tab Self Securing Junction Box Piezo Ignitor Mounting Plate Piezo Wires P i ezo Ignitor Side View Det a i l Fig 5 Typical installation NOTE Gas supply shut off and flex line to the key valve are not supplied Matchlight Fire Pits ...

Page 9: ...cover plate and secure with the plastic mounting nut Insert the positive end of 1 AAA battery into the ingitor module and carefully screw the red button cap to the ignitor module until snug Careful not to over tighten the cap Attach the extension wires PIEZO23WH 25WH to the 2 probe spark ignitor Careful not to overtighten the cap Test the ignitor by pushing and holding the red button to ensure the...

Page 10: ...CAUTION Ensure you have leak tested the fire pit before operating 1 Insert key into gas valve 2 Push and hold the red button on the manual Piezo ignitor and ensure sparking is occurring at the probes inside the fire pit 3 Rotate the key counter clockwise in gas valve to allow gas to flow 4 Gas should ignite within 10 seconds or less If fire pit does not light within 10 seconds turn key clockwise t...

Page 11: ...REV 10 24 12 Page REPLACEMENT PARTS 1 2 3 5 8 6 7 O N O F F Side View 9 10 11 12 13 14 17 Matchlight Fire Pits ...

Page 12: ... shown 1 ST3 100 1030 5 1 2 NPT Conduit Lock Nut 1 ST3 113 1027 6 7 8 Flat Washer Spacer 1 ST3 113 1026 7 3 8 Flex Gas Line 28 inch Length 1 T 100 9898 28 7 1 2 Flex Gas Line 46 inch Length 1 T 200 9898 46 8 Air Shutter Orifice NG 50 Used on 12 Fire Pits 1 FPB 12NGCK 8 Air Shutter Orifice NG 42 Used on 14 Fire Pits 1 FPB 14NGCK 8 Air Shutter Orifice NG 31 Used on 19 20 Fire Pits 1 FPB 19NGCK 8 Air...

Page 13: ...iture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance REV 10 24 12 Page 12 TROUBLE SHOOTING Sympton Remedy Piezo won t spark 1 Be sure battery is installed properly 2 Check battery voltage Min 1 2 VDC needed 3 Check ignitor gap at probes inside fire pit Gap should be at 1 8 4 Doub...

Page 14: ... NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFER ENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT FOR TECHNICAL SERVICE CALL firegear LLC PO Box 871250 Canton MI 48187 888 220 4333 Ext 3 Fax 888 431 0585 WEB SITE www firegearusa com REV 10 24 12 Page 13 CONVERSION KITS OPTIONAL ACCESSORIES The following accessories...

Page 15: ...riod Travel diagnostic cost service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner Fire Gear LLC will not be responsible for labor charges and or damage incurred in installation repair and replace ment or for incidental or consequential damages This Limited Warranty does not cover any failures or operating difficulties d...