background image

Outdoor Fire Pit Pro Spur Burners with

All Weather Electronic Ignition System (AWS)

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

 

This system requires a minimum 18-square inches (per side) of cross ventilation. 

Failure to provide proper ventilation will void the warranty.

Natural Gas Models

Propane Gas Models

Description

FPB-19RPSBR14AWS-N FPB-19RPSBR14AWS-P 19” Round Pan with 14” Pro Brass Burner
FPB-25RPSBR21AWS-N FPB-25RPSBR21AWS-P 25” Round Pan with 21” Pro Brass Burner
FPB-29RPSBR21AWS-N FPB-29RPSBR21AWS-P 29” Round Pan with 21” Pro Brass Burner
FPB-33RPSBR21AWS-N FPB-33RPSBR21AWS-P 33” Round Pan with 21” Pro Brass Burner
FPB-20SPSBR14AWS-N FPB-20SPSBR14AWS-P 20” Square Pan with 14” Pro Brass Burner
FPB-26SPSBR21AWS-N FPB-26SPSBR21AWS-P 26” Square Pan with 21” Pro Brass Burner
FPB-32SPSBR21AWS-N FPB-32SPSBR21AWS-P 32” Square Pan with 21” Pro Brass Burner

Round Pan

MODEL:
SERIAL #:

PN#90188

Square Pan

“PRO SERIES”

Summary of Contents for FPB-19RPSBR14AWS-N

Page 1: ...rovide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 19RPSBR14AWS N FPB 19RPSBR14AWS P 19 Round Pan with 14 Pro Brass Burner FPB 25RPSBR21AWS N FPB 25...

Page 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Page 3: ...lame from distance to ensure that all popping has ceased before fully enjoying the fire CAUTION TABLE OF CONTENTS Specifications 4 Carton Contents Single Fire Feature 5 Preparing a Non Combustible Str...

Page 4: ...As a result your Btu s may vary slightly from Table 2 specifications Table 2 Burner specifications Natural Gas Models Propane Gas Models A Depth B Min Max Opening C Inside Pan Dimension D Ground Level...

Page 5: ...on of the stainless steel flex gas line not supplied with the fire feature see Fig 5 page 9 5 Do not place an LP tank inside any fire pit enclosure Locate all Liquid Propane LP tanks outside the enclo...

Page 6: ...es required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have pro...

Page 7: ...nut connec tions and connectors to prevent moisture issues from the outdoor environment The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the adapter When wir...

Page 8: ...sure the flame is a safe and reasonable height to not pose a risk to people or property Note The Firegear Pro Series brass burners DO NOT USE a primary main burner orifice like a standard stainless st...

Page 9: ...lled inside the enclosure due to the wire length limitations The power cord is 3 feet long the 30VDC leads to the valve are 3 feet long See Fig 5 Fig 7 Example of a single fire feature install with po...

Page 10: ...in detail enables the ability to remove the pan disc to service valve system Flex Frame Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Contr...

Page 11: ...S IMPORTANT DO NOT PLACE ROCK OVER TOP OR UNDER THE PILOT SCREEN COVER The screen must be free of any debris to ensure proper lighting of burner and good flame sense See Fig 13 Cover the burner comple...

Page 12: ...r LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO...

Page 13: ...REV A Page 13 FPB Pro Spur Burners Fire Pits with AWS System AWS REPLACEMENT PARTS GOE 30DCV OUT 1 4 3 2 5 6 7 8 9 10 Items are not to scale...

Page 14: ...rner Cage hood 1 FG PBC 8 Thermopile for primary pilot assembly 1 FG TP 9 Hot Surface Ignition for pilot burner assembly item 2 1 FG HSI 10 Heat Shield 1 FG HEATSHIELD 11 Rocker Switch installs into 7...

Page 15: ...r If for some reason someone connected 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector N...

Page 16: ...osen the thermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the ga...

Page 17: ...effect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a...

Page 18: ...when using paver blocks or other non combustible enclosures Glass Windshields See catalog for a windshield to fit your application Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x F...

Page 19: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Page 20: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Page 21: ...to repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and r...

Page 22: ...company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear O...

Page 23: ...________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...

Reviews: