background image

REV. 4-13-16  Page 5

WARNING: 

Proper clearances from combustible, construction materials must be maintained from all sides, top and    

bottom of this appliance.  Use the specifications listed on page 3 for proper clearance to combustibles.

PREPARING A NON-COMBUSTIBLE STRUCTURE

The fire pit can be installed on a flat, stable surface, away from any combustible materials. Install fire pit on any level, 

outdoor non-combustible, flat, stable surface or a combustible floor according to the clearances specified in this manual.  

NOTE

: Do not place fire pit directly on grass, dirt, or rocks this may prevent proper ventilation (Fig. 3, pg. 4).  

Ensure proper water drainage is also incorporated into the fire pit enclosure.

HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY

NOTE:

  We recommend using ¾” black iron pipe; however please refer to the NFPA54 (National Fuel Gas Code) for 

proper pipe sizing when exceeding 20-feet in length for fire pits rated above 100,000 BTU.

1. Turn 

OFF

 gas supply system. 

NOTE

: All gas connections (except for brass to brass) require the following. Clean pipe 

threads using either a wire brush or steel wool. Apply pipe sealant to the fittings before making any connection. 

BE CAREFUL!

 Ensure all gas connections are snug, but do not over tighten!

2. Extend the gas supply using minimum of ¾” black iron pipe or an approved flexible gas line from existing house 

supply.  This can be accomplished by teeing off or tapping into a gas line connection. Install necessary pipe for the 

distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a foundation 

or house wall, make sure to re-seal the area around the pipe with weather sealant.

3. The primary gas shut-off (not supplied) will require a ½” male flared fitting to enable connection of the stainless steel 

flex gas line supplied with the fire pit (see figure 4).

IMPORTANT

Installation of Natural or LP gas should be done by a qualified installer, service agency or gas supplier.

This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any 

pressure testing of the gas supply piping system at test pressures equal to or less than ½ “psi. (3.5kPa)

VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE

Fire pits are subjected to many outdoor elements such as rain, 

snow, wind, heat or cold.  

A minimum of 18 square inches of 

cross ventilation (2 sides) is required to keep the 

components in good working order. 

 Use figure 5 as a guide. 

Fig 5. Cross Ventilation Example

HIGH ELEVATION INSTALLATION

This appliance is listed for elevations from 0- 4500 feet in Canada 

and the U.S.  If elevation exceeds 4500 feet it may be necessary 

to decrease the input rating by changing the existing burner orifice 

to a smaller size.  Input should be reduced 4% for each 1000 feet 

beyond the 4500 feet above sea level. Check with your local gas 

utility for assistance in determining the proper orifice in your loca-

tion.  In some cases the heating value may already be reduced 

and downsizing the orifice may not be necessary.

(2) 6”x12”

 

Examples of Cross Ventilation

3 - 2”x3” Slots Per Side or

2 - 1” x 9” Slots Per Side or

2- Firegear 6 x12 vents

Cross Flow  Ventilation 

(Min. 18 Sq. In. Per Side)

Fire Pit 

Enclosure

Fire Pit

TFS Linear Fire Pits

Summary of Contents for FPB-24LTFS-N

Page 1: ...For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION PRECAUTION This fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty MODELS Natural Gas Description Propane FPB 24LTFS N 24 Linear Pan Burner FPB 24LTFS P FPB 30LTFS N 30 Linear Pan Burner FPB 30LTFS P FPB 36LTFS N 36 Linear Pan Burner F...

Page 2: ...r appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury of property damage Read the installation operating and mainten...

Page 3: ...a such as i e lava rock lava stones lava boulders has the potential of thermal spalling This is a process that may occur when media is wet and moisture gets trapped inside of the material due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can le...

Page 4: ... proper gas pipe sizing will also affect BTU As a result your BTU may vary slightly from Table 2 specifications Fig 1 Fire Pit dimensions refer to Table 1 Pressure NG LP Min Inlet 5 0 WC 10 5 WC Max Inlet 10 5 WC 13 0 WC Normal Inlet 7 0 WC 11 0 WC Table 3 Gas Pressures Model Natural Gas NG Model Propane Gas LP A Pan Depth B Min Install Length C Burner Tube D Floor Level E Side Wall F Combustible ...

Page 5: ...the cradle brackets Each cradle bracket can be adjusted 1 2 from the top edge of the cradle or lowered to a total of 2 3 4 from the top edge of the cradle There are 1 4 increments to adjust the depth of the fire pit to fit most finishing materials See Fig 4 3 Pilot Covers are decorative spacers that provide equal spacing for all models One side is used as a pilot shield for the pilot system in the...

Page 6: ...hut off valve at the exterior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line supplied with the fire pit see figure 4 IMPORTANT Installation of Natural or LP gas should be done by a q...

Page 7: ...rom the bottom of the burner housing cradle that holds the burner assembly it requires a minimum if of 15 inches to the ground level See page 3 Drainage is critical to ensure that water does not damage gas valve and components Never install the fire pit system below grade 11 CAUTION The fire pit enclosure MUST have a minimum ventilation of 18 square inches on each side of the finished enclosure 12...

Page 8: ...ll white screws provided Batteries can be changed or installed by removing the two screws that hold the cover plate battery pack in place Remove assembly slide cover away from the cover plate and install the 4 four AA batteries 6 Be sure the batteries are installed positive to positive and negative to negative If one battery is installed wrong the system will not operate 7 Once the fire pit is ins...

Page 9: ... See Fig 10 The cover will slide down exposing the gas valve and control module 2 Find the black module attached to the inside of the control box Locate the Learn Button on the bottom of the module 3 Once the Learn button is located press and release the button once You will hear a beep indicating that the module is ready to receive a transmitter code See Fig 11 4 Take the transmitter and press th...

Page 10: ...STALLING PILOT COVER AND PILOT SHIELD Final preparations will require you to install the pilot cover and pilot shield They are wrapped in a protective material to prevent scratches and are inside the carton of the fire pit After you fire tested the fire pit unwrap the pilot cover and pilot shield The pilot cover will sit into place inside each end of the cradle The pilot shield then slides into th...

Page 11: ...urn any solid fuels in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines The direct spark ignition will turn OFF after 20 seconds if the burner does not light after which you will need to press transmitter OFF button then back ON to initiate ignition again Flame height can be adjusted HI and LO After the fire pit is operating pre...

Page 12: ...OWER Learn AUX 13 14 AA Batteries AA Batteries AA Batteries AA Batteries 17 19 Latching Solenoid DC Moror Drive Requires 4 AA 1 5V alkaline batteries Control Box Battery cover slides on off Slide Switch ON OFF 20 5 7 LOW HI OFF ON 21 10 OUT PILOT ADJ IN MAIN PILOT 3 4 11 12 15 16 18 TFS Linear Fire Pits ...

Page 13: ...lenoid 1 AF 4025DSILSS36 11 Pilot Assembly 1 PILOTO23300 206 12 Linear Burner Cradle Bracket 2 CRADLEBRACKET L 13 Linear Burner Ext Bracket 1 EXTBRACKET L 14 Ignition Module 1 VCS 5000MODTC 15 Linear Burner Pilot Shield 2 PILOTSHIELD L 16 Linear Burner Pilot Cover 2 PILOTCOVER L 17 AA Batteries 1 5 Volt used in battery pack 4 BATTAA 18 Valve Box Stainless Steel Lid 1 FIREPITMETALBOXCO 19 Valve Box...

Page 14: ... users if the pilot is not successfully ignited in 20 seconds How to Clear Press OFF then ON buttons to re attempt ignition What to Check 1 Ensure gas supply is turned ON 2 Ensure that the gas line is purged of air Air is common in the gas line if the appliance has just been installed has been disconnected then re connected to the gas line or if the appliance has been unused for an extended period...

Page 15: ...r Sparks at Pilot Hood Frequently During Operation 1 The control module will generate a spark at the ignitor electrode to the pilot hood if the system is in the ON position but does not does not light thermocouple may not be hot enough or generating enough millivolts 2 Make sure that the tip of the thermocouple is clean Soot buildup will insulate the thermocouple and will not allow for proper flam...

Page 16: ...s the use of battery power LP CONVERSION KIT THERE IS NO LP CONVERSION KIT AVAILABLE THESE MODELS YOU MUST ORDER THE FIRE PIT DIRECT FROM THE FACTORY AS PROPANE MODEL 1322 WT Wireless wall switch with ON OFF HI LO MODEL 1001D A Wireless wall switch with ON OFF ONLY MODEL TMR AF1 4 Button Timer with 30 60 120 OFF Minutes Windshields Models GSW 3812 38 long x 12 7 8 wide x 7 1 2 tall GSW4312 43 1 2 ...

Page 17: ... cost service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement This Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cover any defects due to accident abuse...

Page 18: ..._____________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send ph...

Reviews: