background image

REV. C              Page 19

Round/Square Flat Disc Fire Pits

The end-user must provide a bill of sale, canceled check, or payment record to verify the purchase date and to 

establish the warranty period. This Limited Warranty shall be valid and limited to the original purchaser only.

WARNING    Any modification to the product will void the warranty.

This Limited Warranty shall be limited to the repair and/or replacement of parts that have been proven to be 

defective under normal use and service. All warranty claims must be made by the OEM/Distributor/Dealer 

account on behalf of the end-user. You may contact Technical Support at 800-966-8126.

Our Technical Service Department must confirm all approved defects. If a defect is confirmed and we approve 

the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may 

also have other rights, which vary from state to state.

The manufacturer may request defective products returned with an RMA (Return Merchandise Authorization) 

issued by Firegear Outdoors for specific products, which is considered to be the nature of the defect and or 

warranty claim. Product to be returned should; be packed so as not to incur damages during transportation. 

Firegear is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date 

issued. The RMA must be clearly marked on the outside of the package.

Please check with your local building code department or governing agency for proper approvals before 

purchasing. Firegear Outdoors is not responsible for any violation of local codes.

Travel, diagnostic cost, service labor to repair the defect on warranty parts to and from the factory will be the 

responsibility of the owner.  We will not be responsible for labor charges and/or damage incurred in installation, 

repair, and replacement.  Firegear is not responsible for Issues related to gas or electrical installation.  

The Limited Warranty is voided if not assembled, installed, and operated as intended. This Limited Warranty 

does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper 

installation or improper maintenance or service, removal from the original location, or re-installation into 

another location, or failure to perform normal and routine maintenance.

Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due 

to overheating, exposure to chemicals (including chlorine and salt), either directly or in the atmosphere, or very 

high humidity, is not covered by this Limited Warranty. Costal, humid and/or salt environments are subject to 

manufacturer review. All out-of-box claims must be made within 30 days of purchase and must be made prior 

to installation. Any product installed damaged will be considered damaged during installation and not covered 

under warranty.

There are no other express warranties except as set forth herein. For consumer applications, any applicable 

implied warranties of merchantability and fitness are limited induration to the period of coverage of this Limited 

Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation may not 

apply to you.

For Commercial Applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. 

We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular 

purpose or merchantability.

Summary of Contents for FPB-25SFBS22MT-N

Page 1: ...th 22 Burning Spur FPB 29DBS22MT N 29 Round Stainless Flat Pan with 22 Burning Spur FPB 34DBS31MT N 34 Round Stainless Flat Pan with 31 Burning Spur FPB 39DBS36MT N 39 Round Stainless Flat Pan with 36 Burning Spur FPB 44DBS36MT N 44 Round Stainless Flat Pan with 36 Burning Spur FPB 25SFBS22MT N 25 Square Stainless Flat Pan with 22 Burning Spur FPB 30SFBS22MT N 30 Square Stainless Flat Pan with 22 ...

Page 2: ...Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage personal injury of loss of life Read the owner s information manual provided with this appliance Installation and service must be performed by a qualified installer s...

Page 3: ... impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave the area allowing any moisture in the media to dissipate We strongly recommend that during ...

Page 4: ...ing G Combustible Floor FPB 26DBS22MT N 1 16 26 25 8 36 96 18 FPB 29DBS22MT N 1 16 29 28 8 36 96 18 FPB 34DBS31MT N 1 16 34 33 8 36 120 18 FPB 39DBS36MT N 1 16 39 38 8 36 120 18 FPB 44DBS36MT N 1 16 44 43 8 36 120 18 FPB 25SFBS22MT N 1 16 25 24 8 36 96 18 FPB 30SFBS22MT N 1 16 30 29 8 36 96 18 FPB 34SFBS31MT N 1 16 34 33 8 36 120 18 FPB 40SFBS36MT N 1 16 40 39 8 36 120 18 FPB 46SFBS36MT N 1 16 46 ...

Page 5: ...uired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1...

Page 6: ...tting to enable connection of the stainless steel flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or le...

Page 7: ...roved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the top of the burner When purchasing lava rock use 1 to 2 diameter as a base to cover the flat disc 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections must be leak tested before ...

Page 8: ... burning spur clockwise manner Secure into position See Fig 8 Fig 8 Installing OAS assembly to spur burner INSTALLING KEY VALVE The key valve contents 1 key valve 1 key and 1 flange See Fig 9 The valve requires a 1 round clearance hole in the non combustible enclosure wall See the instructions supplied with the key valve for more specific details Note Be sure to leak test all fitting before operat...

Page 9: ...e Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Key Valve Gas Supply Flat Disc Non Combustible Enclousure E Stop Spur Burner Key PUSH TO STOP TURN TO START OFF 0 5 HOURS 1 1 5 2 2 5 Key valve and flexible gas line are supplied gas shut off is not but available in accessories page Flex lines with flared fittings do not require Teflon tape o...

Page 10: ... BVL2S Key Valve Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied Fitting ...

Page 11: ...efore each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 12 Inserting Key into Valve O N O F F Fig 11 Key Valve Face Butan...

Page 12: ...REV C Page 12 Round Square Flat Disc Fire Pits FLAT DISC REPLACEMENT PARTS 1 2 6a Drawings are not to scale 4 6 3 5 7 O N O F F 8 9 G AS PRESSURE REGULATOR 10 11 1A ...

Page 13: ...U1 8D S 9 NPT Female to Male Flare Fitting 1 U3 8D S 10 5 x 3 TMSI cover plate 1 PLATE MT 11 LP Regulator with 32 Hose Not for use with any NG models 1 FG 32LPHRK FLAT DISC REPLACEMENT LIST Item Description Qty Part Number FIRE PIT MAINTENANCE 1 The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person 2 Any component that is found faulty...

Page 14: ...ot provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8D S x Coupling SS499 8 Fig ...

Page 15: ...key valve is fully open See page 9 Fig 10 3 Check for spider webs inside the main burner orifice 4 Check gas pressure Water in my fire pit 1 Excess dust sand material from media may be blocking the weep holes to relieve water Remove all media and unplug weep holes Clean or install new media free of dust and dirt 2 Ensure fire pit enclosure has proper drainage for water and proper ventilation to dr...

Page 16: ...ts Model PAVER KIT MT MSI 2 paver brackets parts and 2 4 inch vents Provides 18 square inches of ventilation per side Model PAVER VENT 4 LNTS 2 paver brackets parts and 2 6 inch vents Provides 18 square inches of ventilation per side Model PAVER VENT 6 LNTS 2 6 x 12 vents and screws Provides 18 square inches of ventilation Model VENT KIT 6X12SS FLEXFRAME Universal brackets to support fire pit disc...

Page 17: ...EAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPT...

Page 18: ...LACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEF...

Page 19: ...pair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not ...

Page 20: ...equential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Phone 800 966 8...

Page 21: ...REV C Page 21 Round Square Flat Disc Fire Pits NOTES ...

Page 22: ...__ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us ...

Reviews: