REV. C Page 9
Firegear Outdoors All Weather Ignition System (AWS)
PREPARING A NON-COMBUSTIBLE STRUCTURE FOR SINGLE INSTALL
POWER SUPPLY LOCATION
The GOE-30VDC power supply is to be installed inside the enclosure due to the wire length limitations. The power cord is
3-feet long the 30VDC leads to the valve are 3-feet long. See Fig. 5.
Non-Pool Certified Applications
Buried Wire (Min.12-gauge) 250’ Max.
120VAC Power
GFI Box with
Weatherproof
Cover
GOE-30VDC
Power Supply
AC Electrical Power
Source from Home
Fire Feature
Buried Gas Line
Key Valve
(Must be 10-feet or more away from pool or spa)
Fig. 5
Example of a single fire feature install.
Note
: Must be 10-feet or more from a pool/spa.
Wall
Switch
Timer
FG-1420-A OD
Remote
Emergency
Stop
(Optional)
FG-PS-30V320
Low Voltage
Power Supply
Key Valve
Electrical Line
Gas Line
ON
OFF
or
or
Main Burner
Flat Pan
Pilot Burner
(Min. 12-gauge)
Pool Certified Applications
Flex Frame (shown in detail)
enables the ability to
remove the pan/disc
to service valve system
Flex
Frame
Min.-Max. Distance
Pilot Run
6” to 22”
(Fire Feature within 5-feet of pool or spa)
Optional ON/OFF
Controls
Note: Actual Power supply must be
10-feet or more from the pool or spa
DETAIL
Pool
Control
Fig. 9a
Example of single fire feature install within 5 feet of a pool or spa.
Note:
Reguires FG-PS-30V320
power supply (purchased seperately). Do not use the GOE-30VDC.
FG-PS-30V320 power supply can be
installed up to a maximum of 500-feet away from fire pit.