REV. 8-9-19 Page 4
AWS Sanctuary 2 & 3 Fire Features
SANCTUARY SPECIFICATIONS
Table 1
Sanctuary Specifications
* Dimension shows disc/pan from combustible floor sitting inside the Sanctuary bowl (See Fig. 2).
Fig 2
. Clearance to Combustibles
(Not to be used in an enclosed space)
Model:
Natural Gas (NG)
NG Factory
Orifice
NG
Btu’s
SAN2-34DBSAWSN-
#29
65,000
SAN3-26DBSAWSN-
#29
65,000
Table 2
Btu Specifications
Model:
Natural Gas (NG)
Uses Fire feature Model:
A
Overall
Width
B
Inside
Width
C
Inside
Depth
D
Height
E
Side
Wall
F
Combustible
Ceiling
G*
Combustible
Floor
SAN2-34DBSAWSN-
FPB-34DBSAWS-N-SAN
38¾”
35¼”
2”
18”
19”
69”
15
1
/
2
”
SAN3-26DBSAWSN-
FPB-26DBSAWS-N-SAN
30”
27½”
2”
14”
19”
69”
12”
Disclaimer:
Btu listings are based on 7.0”WC for Natural Gas and 11.0”WC for Liquid Propane (LP)
to the gas valve. Flex line size and proper gas pipe sizing will also affect Btu’s. As a result your Btu’s
may vary slightly from Table 2 specifications.
WARNING:
Proper clearances from combustible materials must be maintained from all sides, top
and bottom of this appliance. Use the specifications listed for proper clearance to combustibles.
F
E
G*
A
B
C
D
TOP VIEW
4-inch
Diameter
Fig. 1
Sanctuary Dimensions
(SAN2- lower base is 18” wide x 1½” tall)
(SAN3- lower base is 14½ wide x 1¼” tall)
Pressure
NG
LP
Min. Inlet
3.5” WC (⅛ PSI)
8.0” WC (¼ PSI)
Max. Inlet
14.0” WC (½ PSI) 14.0” WC (½ PSI)
Normal Inlet 7.0” WC (¼ PSI)
11.0” WC (⅜ PSI)
Table 3
Gas Pressures