REV. 8-9-19 Page 6
AWS Sanctuary 2 & 3 Fire Features
REFERENCE
GAS PIPE SIZING
Length of Pipe in Feet
1/2”
3/4”
1”
1 - 1/4”
1 - 1/2”
2”
2 - 2 1/2”
3”
4”
10
275
567
1071
2205
3307
6221
10140
17990
35710
20
189
393
732
1496
2299
4331
7046
12510
25520
30
152
315
590
1212
1858
3465
5695
10110
20620
40
129
267
504
1039
1559
2992
4778
8481
17300
50
114
237
448
913
1417
2646
4343
7708
15730
60
103
217
409
834
1275
2394
3908
6936
14150
70
89
185
346
724
1086
2047
3329
5908
12050
80
78
162
307
630
976
1811
2991
5309
10830
90
69
146
275
567
866
1606
2654
4711
9613
100
63
132
252
511
787
1496
2412
4281
8736
125
54
112
209
439
665
1282
2083
3618
7382
150
48
100
185
390
590
1138
1808
3210
6549
175
43
90
168
353
534
1030
1637
2905
5927
200
40
83
155
325
491
947
1505
2671
5450
300
37
77
144
303
458
887
1404
2492
5084
NATURAL GAS : PIPE SIZING CHART
•
Natural Gas (NG) flow is given in
thousands of BTU/hr. = 1 cubic
foot of NG gas - 1000 BTU
•
Nominal pressure at the burner
for Natural Gas is 3.5” of water
column. (Typical machine supply
5”-7”)
•
Pipe length must include
additional length for all fittings.
Add approximately 5 feet of pipe
per fitting.
•
Natural Gas Example: A machine
with a burner that requires
440,000 BTU would need a 1 -1/4”
pipe for a 20” long run.
LIQUID PROPANE : PIPE SIZING CHART
NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you
are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper
pressure.
This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel
Gas Code - current edition) for more details.
Length of Pipe in Feet
1/2”
3/4”
1”
1 - 1/4”
1 - 1/2”
2”
2 - 2 1/2”
3”
4”
10
108
230
387
793
1237
2259
3640
6434
-
20
75
160
280
569
877
1610
2613
5236
9521
30
61
129
224
471
719
1335
2165
4107
7859
40
52
110
196
401
635
1143
1867
3258
6795
50
46
98
177
364
560
1041
1680
2936
6142
60
42
89
159
336
513
957
1559
2684
5647
70
38
82
149
317
476
896
1447
2492
5250
80
36
76
140
239
443
840
1353
2315
4900
90
33
71
133
275
420
793
1288
2203
4667
100
32
68
126
266
411
775
1246
2128
4518
125
28
60
117
243
369
700
1143
1904
4065
150
25
54
105
215
327
625
1008
1689
3645
175
23
50
93
196
303
583
993
1554
3370
200
22
47
84
182
280
541
877
1437
3160
300
17
37
70
145
224
439
686
1139
2539
•
Liquid Propane (LP) Gas flow is
given in thousands of BTU/hr. =
1 cubic foot of LP gas - 2500 BTU.
•
This chart refers to low pressure LP,
after regulation, Standard nominal
pressure at the burner for Liquid
Propane Gas is 11” of water column.
•
Pipe length must include additional
length for all fittings. Add
approximately 5 feet of pipe per
fitting.
•
LP Example: A machine with a
burner that requires 440,000 BTU
would need a 1” pipe for a 20’ long
run.
GAS PIPE SIZING CHART
Table 4
Gas Pipe Sizing Chart