background image

REV. 8-9-19  Page 7

AWS Sanctuary 2 & 3 Fire Features

PRE-INSTALLATON CHECK LIST FOR SINGLE INSTALL

GAS INFORMATION

Gas Volume

 - Ensure the correct size pipe is used for 

the total gas load.  If installing more than one fire feature, 

ensure the correct size pipe is based upon the distance of 

the furthest fire feature away and the total gas load is for 

all gas appliances on that gas line (i.e. fire feature, BBQ, 

torches, etc.).

Gas Pressure & Type of Gas 

- Verify the gas pressure 

being supplied to the fire features?  Is the fire feature(s) 

configured for the proper gas type? The AWS gas valve is 

shipped for Natural gas (NG). To convert to Propane (LP) 

gas, the secondary pilot orifice must be changed.

 

Manual Shut-off/Key Valve 

- A manual shut-off or key 

valve installed into of the fire feature? 

Purging a New Gas Line

 - Has the gas line been purged 

of both air and possible debris?  Any gas lines buried 

underground must be pressure tested up to 60PSI to 

ensure no leaks.  After inspection is complete, most 

plumbers will release pressure in the line at one location by 

opening the manual ball/key valve.  It is recommended to 

release pressure by opening a ball/key valves associated 

with all the fire features.  

Example

: There are four fire 

features on a job, open the first key valve for a few 

seconds, then close it. Then move on to the next key valve 

and do the same thing until you have purged the debris out 

of all four gas lines. 

Main Burner Orifice

 - All fire features 

MUST

 have a main 

burner orifice installed on the inlet side of the burner.  An 

orifice limits the amount of gas flow to the burner to 

ensure the flame is a safe and reasonable height to not 

pose a risk to people or property. The drawings below show 

the difference between a Natural Gas (NG) and Propane 

(LP) orifice.  LP gas requires ventilation holes at the base 

of the orifice to provide a cleaner flame. See Fig. 3.

ELECTRICAL INFORMATION

Wire Gauge

 - Is the wire gauge correct?  Wiring must be 

12AWG or greater (solid or stranded) for all installations. 

Note:

 It is recommended to fill the wire nuts with either 

dielectric grease or silicone prior to installing the wire nut. 

This will ensure a waterproof connection. 

Why GFI circuit?

 A GFI is a type of circuit breaker which 

shuts off electric power when it senses an imbalance 

between the outgoing and incoming current. It protects the 

house wires and receptacles from overheating and possible 

fire.

Power Supply

 - Firegear Outdoors provides one 

GOE-30VDC power supply with each Sanctuary model. 

The power supply requires 120VAC power to operate and 

converts it to 30VDC to operate the gas valve.  

DO NOT 

CONNECT 120VAC DIRECTLY TO THE GAS VALVE 

WIRES - DAMAGE WILL OCCUR. THIS IS NOT 

COVERED BY WARRANTY.

  The #GOE-30VDC is used 

for one fire feature only and must be installed 10-feet or 

greater from any pool or spa.  This power supply has a 

3-foot power cord to plug into 120VAC outlet and a 3-foot 

leads to connect to the gas valve on the 30VDC side.

MEDIA INFORMATION

Acceptable media placed over top of the burner:  

 

Lava Rock 

 

Min.1”- 2” size

  

 

FG-LAVA-10 (10 LBS.)

 

 

FG-LAVA-50 (50 LBS.)

GL Glass

 

Min. ½” - ¾” size

 

 

Various colors are available

 

 

See Product catalog for details 

 

 

          

   

Sold in 5 LB. bags or 8 bags to a 

case

GRL Reflective Glass

  Min. ½” - ¾” size

 

 

Various colors are available

 

 

See Product catalog for details   

 

  

Sold in 5 LB. bags or 8 bags to a case

DRAINAGE INFORMATION

For any fire feature ABOVE ground level requires a drain/

holes line or a way for water to exit the fire feature. 

Note: This AWS system is not approved to be installed 

BELOW ground level.

NG

LP

Fig. 4 

  Natural (NG) orifice on left; LP (vent holes) on right.

Summary of Contents for FPB-26DBSAWS-N-SAN

Page 1: ...as Description SAN2 34DBSAWSN 38 x 18 Concrete Bowl SAN3 26DBSAWSN 30 x 14 Concrete Bowl Sanctuary 2 Sanctuary 3 THE ROUND FLAT DISC SYSTEM FOR THE SANCTUARY 2 3 COMES WITH A SEPARATE CARTON AND MANUAL HOWEVER USE THIS MANUAL FOR ACTUAL INSTALLATION INTO THE SANCTUARY BOWLS DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL Bowls c...

Page 2: ...re department DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installati...

Page 3: ...hich is known to the State of California to cause birth defects or other reproductive harm For more information go to www p65Warnings ca gov All media i e lava rock lava stones lava boulders and fire glass has the potential of thermal spalling This is a process that may occur when media is wet and moisture gets trapped inside of the material due to rapid temperature differences When this happens t...

Page 4: ...8 35 2 18 19 69 15 1 2 SAN3 26DBSAWSN FPB 26DBSAWS N SAN 30 27 2 14 19 69 12 Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP to the gas valve Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications WARNING Proper clearances from combustible materials must be maintained from a...

Page 5: ...or base then install the GFI box and remote control receiver inside the pedestal or base HARD PIPING TO FIRE FEATURE WITHOUT GAS PROXIMITY NOTE Refer to the NFPA54 National Fuel Gas Code for proper pipe sizing See gas line sizing chart on page 6 of this manual as a reference 1 Turn OFF gas supply system NOTE All gas connections except for brass to brass require the following Clean pipe threads usi...

Page 6: ...equired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1...

Page 7: ...low show the difference between a Natural Gas NG and Propane LP orifice LP gas requires ventilation holes at the base of the orifice to provide a cleaner flame See Fig 3 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to in...

Page 8: ...Ventilation is built into the bottom of each concrete fire feature No additional vents are required WARNING DO NOT BURY THE BOTTOM OF THE CONCRETE BOWL INTO EARTH OR OTHER TYPE OF MEDIA THIS CAN OBSTRUCT AIR FLOW VENTILATION AND VOID FIREGEAR WARRANTY INSTALLATION REQUIREMENTS OF ALL FIRE FEATURES IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or...

Page 9: ...ate into the bowl Fig 6 Typical MT installation 49 88 BRASS ELBOW CRV BVL2CP BVL2S Key Valve MT FACEPLATE 49 88 BRASS ELBOW Fig 5 Assembled MT mounting plate MT Mounting Plate Detail KEY VALVE ASSEMBLY The figure drawing below shows the MT mounting plate parts and pieces used for the assembly This is pre assembled and ready to install See Fig 5 The Key Valve Assembly consists of 1 key valve and fl...

Page 10: ...h wire nut See Fig 8 Note An extra red jumper wire is provided to extend either one of the red wires of the FG 1420 AOD remote control receiver if needed It is not required to use this wire It depends on each application DO NOT CONNECT 120VAC DIRECTLY TO THE GAS VALVE WIRES DAMAGE WILL OCCUR THIS IS NOT COVERED BY WARRANTY LEARN Weather Proof Box AWS Valve Box GFI Box GOE 30VDC Power Supply FG 142...

Page 11: ...rock Sanctuary 3 uses 24 LBS of Firegear Outdoor lava rock Lava rock height should be level and no higher than the top lip of the bowl approximately 2 depth from burner pan Fig 11 MedIa lava rock installation Attach another flex line to the top fitting and connect the other end to the flared fitting of the gas valve box Securely tighten all fittings Install the assembled pan into the bowl as shown...

Page 12: ...wer vents AWS EXPANED VIEW Hard Pipe Gas Supply Key Valve AWS Burner Pan Assembly Vent Remote Power Supply GFI Box w weather proof cover Remote Receiver w weather proof cover The installation shown above is a Sanctuary 2 Fire Feature The Sanctuary 3 does not have enough room for the GFI power box and the FG 1420 A OD remote receiver they will require external mounting outside of the bowl ...

Page 13: ... cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING AND THE TRANSMITTER AND RECEIVER HAVE BEEN LEARNED PROGRAMED TOGETHER FOR WIRELESS OPERATION WARNING Do not stand overtop of fire feature during ignition or operation due to high surface...

Page 14: ...8 9 19 Page 14 AWS Sanctuary 2 3 Fire Features Junction Box Weatherproof Cover Lid GOE 30DCV SANCTUARY 2 3 REPLACEMENT PARTS 1 2 4 5 3 Drawings No to Scale 12 18 13 14 15 16 17 7 20 21 8 9 11 10 6 OUT 19 22 ...

Page 15: ...ve flange used with BVSL2S 1 CRV BVL2CP 9 Key Valve 1 BVL2S 10 Flare x MIP Brass Elbow used with BVL2S MT models 2 49 88 11 Air Shutter Orifice Natural Gas NG 1 OAS NG29 12 Air Shutter Orifice Propane Gas LP 1 OAS LP41 13 12 Chrome Plated Key 1 KEY PC 12 14 Ignition Control Box Valve box only 1 FG ICB 15 AWS Pilot Assembly 1 FG PBA 16 30VDC Transformer 1 GOE 30VDC 17 Heat Shield 1 FG HEATSHIELD 18...

Page 16: ...arance Our products are sealed prior to shipment but the continued care and resealing of the product will be needed every 4 5 years to protect the appearance With a concrete sealant your concrete will look great and natural for many occasions Prolonged contact with overly acidic heavily pigmented or alkali substances should be avoided We recommend cleaning any spills as quickly as possible Take ca...

Page 17: ...ed directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present replace controller Connector Not Plugged In Correctly Check the 2 pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If loose push...

Page 18: ...lide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then replace it Defective Controller or Main Gas Valve If you have inspected the the...

Page 19: ...ns the trapped gas in the fire feature ignites and you see the Flare Up effect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas NG is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas NG will rise to the top of the feature Once it encounters th...

Page 20: ...imary pilot orifice FG PBO LP to convert Natural gas pilot to LP gas Note Requires new LP main burner orifice OAS LP41 sold separately Timer Electric mechanical 2 hour timer Model FG TIMER 2HR Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Emergency Stop Model FG EMER STOP Electric emergency shut off Pool Sp...

Page 21: ... another location or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemicals including salt either directly or in the atmosphere or very high humidity is not covered by this Limited Warranty There are no other express warranties except as set forth herein For cons...

Page 22: ... NEED THIS INFORMATION 1 Model Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Pl...