SECTION B THERMOCOUPLE MANUAL
SAFETY
INST
ALLA
TION
INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE
INSTALLING GAS VALVE
The gas valve is secured into the mounting plate with a nut.
Figure 12 shows an example of a typical installation.
Fig. 12 Gas valve components.
Mounting Stem
with Securing
Nut
Primary Inlet
Gas Supply
Gas Outlet
to Fire Pit
Thermocouple
Connection
Control
Knob
Valve Mounting
Plate
Fig. 10 Shows disc secured under stone caps.
Fig.11 Shows disc secured between layer of block.
Flat disc pans are for use with landscape blocks. The illustrations below show examples of possible installations.
REV. 5-7-14 Page 10
Flat Disc Burning Spur Fire Pits
REQUIREMENTS
1. Only non-combustible materials should come in direct contact with any part of the fire pit. Underneath area should
be non-combustible or a flat level combustible surface according to the clearances specified in this manual.
2. We recommend using 3/4” black iron pipe; however please refer to the NFPA54 (National Fuel Gas Code) for proper
pipe sizing when exceeding 20-feet in length for fire pits rated above 100,000 BTU’s.
3. Determine the size of the round fire pit you are preparing to install (Refer to page 3).
4. You must provide a round opening out to place the flat disc onto the non-combustible enclosure. Do not exceed the
maximum opening from Table 1, dimension B located on page 3.
5. Follow the local code requirements for the gas type being used. This fire pit should be installed in accordance with
local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1
NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.
6. Fire pits create high temperatures, it is very important to have any combustibles at a safe distance. Refer to page 3.
7.
CAUTION:
A minimum of 18 square inches of cross ventilation (per side) is required to keep enclosure dry.
8. These products are designed for outdoor use only. Not approved for any indoor use.
9. This fire pit is designed to have lava rock completely covering the spur burner, so that the burner is not visible.
Do not cover more than 1” above the top of the burner. When purchasing lava rock use 1” diameter as a base to fill
the flat disc.
10.
Gas lines and fittings must be installed in to the non-combustible structure. All gas connections must be leak
tested before installation of the fire pit. Soapy water leak detection is required before regular use of fire pit.
11. Do not use material that will absorb moisture over time and will not release this moisture quickly. Moisture can boil
in this material and can rapidly break apart and cause damage or personal injury.
12. Never leave any other combustible material on top of the fire pit. This could cause unsafe operation of this system
and damage to the component that will not be covered under our warranty.
13 .