Firegear Outdoor KWB30
11
INSTALLATION
37-15/16" (964mm)
TOP VIEW
SIDE VIEW
END VIEW
8-3/4" (222mm)
8-3/4" (222mm)
10-7/8" (276mm)
37-15/16" (964mm)
INNER FRAMING DIMENSIONS (REQUIRED)
NOTE:FRAMING MATERIAL NOT SUPPLIED
KWB60
KWB30
NOTE:
Framing materials may be combustible or non-
combustible.
Finishing materials
MUST
be non-combustible.
Consideration should be given to weather / elements
when choosing framing materials (ie. treated lumber,
steel stud).
NOTE:
KWB30 - Two (2) ventilation grills are required for all
enclosures.
KWB60 - Four (4) ventilation grills are required for all
enclosures - 2 on each end.
This is to alleviate moisture and allow for air to circulate.
Minimum recommended size 20" sq (508 mm²)
ea
.
Finished material cutout dimensions:36-7/16" L x 8-1/4"W
66-15/16" (1700mm)
END VIEW
8-3/4" (222mm)
8-3/4" (222mm)
SIDE VIEW
66-15/16" (1700mm)
10-7/8" (276mm)
TOP VIEW
Vent Location
Vent Location
Vent Location
Vent Location
Vent Location
Vent Location
NOTE:
KWB60* is two KWB30 units assembled end to end.
Finished material cutout dimensions: 66-7/16" L x 8-1/4"W