32
Firegear Outdoor KWB30
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
1. Turn off gas supply
2
. Remove the pilot shield.
3.
Remove fi reglass, garden stones and twig set, if installed.
4.
Locate and remove 9 screws to remove the burner tray.
8.
Turn off gas supply and remove fl ex connection at valve.
9.
Remove orange EV1 wire connected to the gas valve.
10.
Remove green EV2 wire connected to the gas valve.
11.
Remove 8 screws securing valve assembly.
12.
Lift valve assembly up and out.
13.
Remove both yellow/green ground wires from valve and valve bracket.
14.
Replace valve assembly gasket if necessary.
15.
Rotate HI/LO modulating valve all the way to the left for HI position.
16.
Install new valve assembly and reverse steps 12-1.
17.
Test gas connections for leaks.
Turn the unit off and allow to cool to room temperature.
5.
Lift burner tray off.
6.
Slide burner tube to the right off burner orifi ce and lift out.
7.
Remove 6 screws on valve access cover.