14
Firegear Outdoors® Key West™ Series
INSTALLATION
CONVERSION FROM LP TO NG
2.
Slide burner to the left, away from the pilot orifi ce and lift out.
3.
Locate LP burner orifi ce.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one NG Conversion Kit
Conversion Kit Contains:
Qty. Part
#
Description
1
904-989
Burner Orifi ce #23
1
908-529
Yellow NG Label
1
909-265
Max 0.5 PSI Label
1
286-035
Regulator Mounting Base
1 911-135 Regulator
NG
1
904-978
3/8" fl ex pipe black (18" length)
4 904-959 Phillips
screws
1 919-342 Instruction
Sheet
4.
Remove burner orifi ce with a 1/2" wrench. Use another wrench to hold on
to the elbow behind the orifi ce. Discard orifi ce.
1.
Remove burner by removing 4 screws in locations shown below. If glass
crystals are installed, move the crystals out of the way to reveal screws.
Turn the unit off and allow to cool to room temperature.
Remove leaf cover and any media (glass etc) if installed.
Remove Table Top - see instructions in this manual.
5
. Adjust aeration setting to fully closed for NG.
6
. Reinstall burner.
7
. Remove gas knob by pulling off - then remove end panel by lifting up
and off.
Diagram 6
Diagram 7
Diagram 8
Diagram 5
Diagram 2
Diagram 1
Diagram 3
Summary of Contents for KWBH-2
Page 6: ...6 Firegear Outdoors Key West Series DIMENSIONS UNIT DIMENSIONS DINING HEIGHT ...
Page 7: ...Firegear Outdoors Key West Series 7 DIMENSIONS UNIT DIMENSIONS BAR HEIGHT ...
Page 35: ...Firegear Outdoors Key West Series 35 PARTS LIST DINING AND BAR HEIGHT ...
Page 36: ...36 Firegear Outdoors Key West Series PARTS LIST COFFEE HEIGHT ...
Page 37: ...Firegear Outdoors Key West Series 37 NOTES ...