REV. 8-30-18  Page 6

Linear Outdoor Fire (LOF)

WARNING: 

Proper clearances from combustible, construction and materials must be maintained from all sides, top and 

bottom of this appliance.  This appliance should never be placed on any combustible surface.  This appliance should 

never be placed under any combustibles closer then 96-inches. This appliance should never be placed closer than 
36-inches from any side to any combustible construction or materials (See fig. 2, pg. 3).

PREPARING A NON-COMBUSTIBLE STRUCTURE

The Linear Outdoor Fire is to be installed on a flat, stable surface, away from any combustible materials. Install Linear 

Outdoor Fire on any level, outdoor non-combustible surface. 

NOTE

: Do not place Linear Outdoor Fire directly on grass, 

dirt, or rocks this may prevent proper ventilation (Fig. 1, pg. 3).  

Ensure proper water drainage is also incorporated 

into the Linear Outdoor Fire enclosure.

HARD PIPING TO Linear Outdoor Fire pit WITHOUT GAS PROXIMITY

NOTE:

  We recommend using a minimum ¾” black iron pipe however refer to the NFPA54 (National Fuel Gas Code) for 

proper pipe sizing when exceeding 20-feet in length for Linear Outdoor Fire’s rated above 100,000 Btu’s.

1. Turn 

OFF

 gas supply system. 

NOTE

: All gas connections (except for brass to brass) require the following. Clean pipe 

threads using either a wire brush or steel wool. Apply Teflon tape or pipe sealant to the steel fittings before making any 

connection. 

BE CAREFUL!

 Ensure all gas connections are snug, but not over tighten!

2. Extend the gas supply system using minimum of ¾” black iron pipe or an approved flexible gas line from existing house 

supply.  This can be accomplished by teeing off or tapping into a convenient gas line connection. Install necessary pipe 

for the distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a 

foundation or house wall, make sure to re-seal the area around the pipe with weather sealant.

3. the primary shut-off (not supplied) will reguire a 1/2” male flared fitting to enable connection of stainless steel flex

IMPORTANT

Installation of Natural or LP gas should be done by a qualified installer, service agency or gas supplier.

The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any   

pressure testing of the system at test pressure testing of the system at test pressures in excess of ½ psig (3.5kPa).

This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any 

pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa)

NOTE: 

LP conversion kits are available in the Accessory/      

Conversion Kit section of this manual.  When converting a Linear 

Outdoor Fire ensure you follow the instructions supplied with the 
conversion kit

.

VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE

Linear Outdoor Fire’s are subjected to many outdoor              

elements such as rain, snow, wind, heat or cold.  

A minimum 

of 18 square inches of cross ventilation (2 sides) is 

required to keep the components in good working order. 

 

Use figure 3 as guide to assist to incorporate proper 

ventilation.  

NOTE

: Ventilation is not required at the bottom, it  

may also be incorporated in the upper portion of an enclosure.  

Fig. 3

 Cross Ventilation Example

HIGH ELEVATION INSTALLATION

This appliance is listed for elevations from 0-4500 feet in 

Canada and the U.S.  If elevation exceeds 4500 feet it may be 

necessary to decrease the input rating by changing the exist-

ing burner orifice to a smaller size.  Input should be reduced 

4% for each 1000 feet beyond the 4500 feet above sea level. 

Check with your local gas utility for assistance in determining 

the proper orifice in your location.  In some cases the heating 

value may already be reduced and downsizing the orifice may 

not be necessary.

(2) 6”x12”

 

Examples of Cross Ventilation

3 - 2”x3” Slots Per Side or

2 - 1” x 9” Slots Per Side or

2- Firegear 6 x12 vents

Cross Flow  Ventilation 

(Min. 18 Sq. In. Per Side)

Fire Pit 

Enclosure

Fire Pit

Summary of Contents for Linear Outdoor Fire

Page 1: ...r Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION PRECAUTION This Linear Outdoor Fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Match Throw Description Manual Spark LOF 30MT N 30 inch stainless burner pan LOF 30MSI N LOF 36MT N 36 inch stainless burner pan LOF 36MSI N MODELS ...

Page 2: ...ave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury of property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions is not f...

Page 3: ...a is wet and moisture gets trapped inside of the material due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop A...

Page 4: ...t provide a minimum of 1 2 square inches 3 23 cm for each pound of propane LP contained in the tank see example below Every opening must have minimum dimensions to allow entrance of a 1 2 3 2 mm diameter rod Ventilation openings in side walls must not communi cate directly with other enclosures of the Linear Out door Fire pit The cylinder valve must be easily accessible by hand Connections should ...

Page 5: ...36MT N LOF 36MSI N 75 000 Btu s 29 41 NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model A Pan Depth B Min Max Opening Width Length C Inside Pan D Ground Level LOF 30MT N LOF 30MSI N 2 6 7 W x 30 31 L 30 6 LOF 36MT N LOF 36MSI N 2 6 7 W x 36 37 L 36 6 Note Linear Outdoor Fire s are rated at maximum Btu s which is dependent upon proper gas pipe sizing Flex line siz...

Page 6: ...und the pipe with weather sealant 3 the primary shut off not supplied will reguire a 1 2 male flared fitting to enable connection of stainless steel flex IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of th...

Page 7: ...corative glass covering may be loosely scattered on top of the rock if desired or non combustible logs may be added for a campfire look If logs are chosen do not place on decorative glass base use only Lava Rock as the base NOTE If using all glass media glass must be a minimum of diameter or larger 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections ...

Page 8: ...upply shut off and flex line to the key valve are not supplied Key Valve Gas Supply Fire Pit Pan Non Combustible Fire Pit Enclousure MSI Piezo Ignitor Kit Non Combustible Wall Material Non Combustible Wall Material Securing Tab Securing Tab Self Securing Junction Box Piezo Ignitor Mounting Plate Piezo Wires Piezo Ingnitor Side View D e t a i l Fig 5 Typical Installation ...

Page 9: ...s are directly overtop of a burner port hole The sparking probes must be in the path of a flame to ignite the gas for proper ignition of the flame Replace the screen cover and follow the operating instructions INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock media into the burner pan Ensure the media is a minimum of 1 inch diameter for proper operation Note Do not pour Lava Rock dir...

Page 10: ...missible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause sever burns if contacted 2 Do not burn any solid fuels in this appliance CAUTION Ensure you have leak tested the Linear Outdoor Fire before operating 1 Insert key into gas valve 2 Push and hold the red button on the manual Piezo ignitor and ensure spark...

Page 11: ...REV 8 30 18 Page 11 Linear Outdoor Fire LOF REPLACEMENT PARTS 1 2 5 3 4 O N O F F Side View 6 15 7 9 10 11 14 12 13 AAA Battery 8 DRAWINGS NOT TO SCALE ...

Page 12: ...42 RB 9 Ignitor Module Cover Plate w Screws MT FACEPLATE 10 2 Probe Manual Spark Ignitor 1 Sold with MSI models only 11 AAA Battery 1 BATTAAA 12 Junction Box With Self Securing Tabs 1 JUNCTIONBOX 13 Std Capacity Straight Ball Valve 1 BVL2S 14 8 inch Chrome Key for BVS 1 KEY PC 12 15 Chrome Flange decorative chrome cover for BVS 1 CVR BVL2CP 16 23 Piezo wire not shown 1 PIEZO23WH 17 25 Piezo wire n...

Page 13: ...le brush or cloth Keep soot away from clothing or furniture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TROUBLE SHOOTING Symptom Remedy Piezo Won t Spark 1 Be sure battery is installed properly 2 Check battery voltage Min 1 2 volts needed 3 Check ignitor gap at probes inside L...

Page 14: ... Key Valve U1 8D S U1 8D S Fitting Inlet Gas Supply Expanded View of Match Throw LOF Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 15: ...REV 8 30 18 Page 15 Linear Outdoor Fire LOF NOTES ...

Page 16: ... Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 ...

Reviews: