REV. C Page 5
Drop in Pan - Match Throw Fire Pits
Fig. 3
T-style burner pan specifications.
MODELS
N=NG; P=LP
INSIDE PAN
DIMENSIONS
A
OUTSIDE PAN
DIMENSIONS
B
BURNER
LENGTH
CUTOUT
DIMENSIONS
GROUND
LEVEL
SIDE
WALL
COMBUSTILE
CEILING
COMBUSTIBLE
FLOOR
LOF-2406TMT-N
LOF-2406TMT-P
24” x 6”
(609 x 152mm)
26
½”
x 8
½”
(673 x 215mm)
21”
(533mm)
25” x 7”
(635 x 178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-3006TMT-N
LOF-3006TMT-P
30” x 6”
(762 x 152mm)
32
½” x
8
½”
(825 x 215mm)
27”
(686mm)
31” x 7”
(787 x 178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-3606TMT-N
LOF-3606TMT-P
36” x 6”
(914 x 152mm)
38
½” x
8
½”
(977 x 215mm)
33”
(838mm)
37” x 7”
(787 x 178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-4806TMT-N
LOF-4806TMT-P
48” x 6”
(1219 X 152mm)
50
½” x
8
½”
(1280 x 215mm)
45”
(1143mm)
49” x 7”
(1244 x178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-6006TMT-N
LOF-6006TMT-P
60” x 6”
(1524 x 152mm)
62
½” x
8
½”
(1587 x 215mm)
57”
(1448mm)
61” x 7”
(1549 x 178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-7206TMT-N
LOF-7206TMT-P
72” x 6”
(1828 x 152mm)
74
½” x
8
½”
(1892 x 215mm)
69”
(1752mm)
73” x 7”
(1854 x 178mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-8406TMT-N
LOF-8406TMT-P
84” x 6”
(2133 x 152mm)
86
½” x
8
½”
(2197 x 215mm)
81”
(2057mm)
85” x 7”
(2159 x 178mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
LOF-9606TMT-N
LOF-9606TMT-P
96” x 6”
(2438 x 152mm)
98
½” x
8
½”
(2501 x 215mm)
93”
(2362mm)
97” x 7”
(2463 x 178mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
SPECIFICATIONS
Models:
N=NG; P=LP
NG
Orifice
Btu
Ratings
LP
Orifice
LOF-2406TMT-N
LOF-2406TMT-P
#34
50,000
(14.65kW)
#47
LOF-3006TMT-N
LOF-3006TMT-P
#34
50,000
(14.65kW)
#47
LOF-3606TMT-N
LOF-3606TMT-P
#29
75,000
(21.98kW)
#41
LOF-4806TMT-N
LOF-4806TMT-P
#22
100,000
(29.30kW)
#35
LOF-6006TMT-N
LOF-6006TMT-P
#16
125,000
(36.63kW)
#31
LOF-7206TMT-N
LOF-7206TMT-P
#11
150,000
(43.96kW)
#29
LOF-8406TMT-N
LOF-8406TMT-P
#05
175,000
(51.28kW)
#26
LOF-9606TMT-N
LOF-9606TMT-P
#02
200,000
(58.61kPA)
#22
Table 3
Fire Pit Dimensions
Pressure
NG
LP
Min. Inlet
5.0” WC
(1.24kPa)
10.5” WC
(2.61kPa)
Max. Inlet
10.5” WC
(2.61kPa)
13.0” WC
(3.23kPa)
Normal Inlet
7.0” WC
(1.74kPa)
11.0” WC
(2.73kPa)
Table 4
T-burner specifications.
Table 5
Gas pressures.
A
B
A
2½”
3/8”
1¼”
END VIEW
B
Disclaimer:
Btu listings are based on 7.0”WC for
Natural Gas and 11.0”WC for Liquid Propane (LP) at
the burner orifice. Flex line size and proper gas pipe
sizing will also affect Btu’s. As a result your Btu’s may
vary slightly from Table 2
specifications.