REV. A Page 10
Drop in Pan - AWS Fire Pits
GOE-30VDC Power Supply
Flex Gas Line
AWS Burner Pan Assembly
Carton Contents
Hardware
Bag
REMOVING FIRE PIT ASSEMBLY FROM CARTON
Open carton and remove contents. Inspect for any
damage or missing parts.
Before the fire pit is set inside the enclosure, install the 46”
flex connector to the gas valve box and to the manual key
valve.
This system is provided with a hand held remote control
(Model 1420-A). Wire it as shown in Figs. 23 and 24. The
remote control receiver will fit inside the weatherproof box
(provided). Use the instructions provided with the remote
control to “learn” (program) the transmitter to the receiver.
Use dielectric grease on all wire nut connections and ¼”
connectors to prevent moisture issues from the outdoor
environment.
Fig. 8
Shows carton contents.
Note
: H-burner was illustrated for this drawing.
The AWS system is polarity sensitive. There is a red
sleeve attached to the positive (+) side of the adapter.
When wiring the remote control receiver, one red wire from
the receiver connects to the adapter with the red sleeve.
The other red wire of the receiver connects directly to the
red wire from the gas valve control box. See Figs. 9 and
10 on page 11.
Carefully install the fire pit into the prepared enclosure,
connect the gas line and wire according to the figure
drawings in this manual.